<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">ARS</journal-id><journal-title-group>
    <journal-title>Advances in Radio Science</journal-title>
    <abbrev-journal-title abbrev-type="publisher">ARS</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Adv. Radio Sci.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1684-9973</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/ars-18-17-2020</article-id><title-group><article-title>Near-Field Antenna Measurements with Manual Collection <?xmltex \hack{\break}?>of the Measurement Samples</article-title><alt-title>Manual Near-Field Antenna Measurement</alt-title>
      </title-group><?xmltex \runningtitle{Manual Near-Field Antenna Measurement}?><?xmltex \runningauthor{F.~T.~Faul et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Faul</surname><given-names>Fabian T.</given-names></name>
          <email>fabian.faul@tum.de</email>
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Steiner</surname><given-names>Hans-Jürgen</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Eibert</surname><given-names>Thomas F.</given-names></name>
          
        </contrib>
        <aff id="aff1"><label>1</label><institution>Chair of High-Frequency Engineering, Department of Electrical and Computer Engineering,  Technical University <?xmltex \hack{\break}?>of Munich, 80290 Munich, Germany</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Aeroxess UG, 81925 Munich, Germany</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Fabian T. Faul (fabian.faul@tum.de)</corresp></author-notes><pub-date><day>10</day><month>December</month><year>2020</year></pub-date>
      
      <volume>18</volume>
      <fpage>17</fpage><lpage>22</lpage>
      <history>
        <date date-type="received"><day>28</day><month>February</month><year>2020</year></date>
           <date date-type="rev-recd"><day>27</day><month>April</month><year>2020</year></date>
           <date date-type="accepted"><day>28</day><month>April</month><year>2020</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2020 Fabian T. Faul et al.</copyright-statement>
        <copyright-year>2020</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020.html">This article is available from https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020.html</self-uri><self-uri xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020.pdf">The full text article is available as a PDF file from https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e103">Near-field measurements are commonly performed in anechoic chambers which limits the flexibility of the measurements and requires high precision equipment to achieve exact results. In this contribution, we investigate a simple near-field measurement setup which does not use any sophisticated positioning system nor operates in a controlled environment. Instead, the probe antenna is moved by an operator person while the probe position is measured by a laser tracker. This implies that the measurement results will have a higher error level in comparison with antenna chamber measurements. However, excellent error levels are not always necessary, especially when it comes to on-site testing of the principle functionality of antennas. Measurement results are shown to illustrate the performance of the system.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e115">Antennas are usually characterized in terms of their far-field (FF) radiation pattern. An efficient method to obtain the pattern involves near-field (NF) measurements from which the FF can be calculated by a NF to FF transformation (NFFFT) <xref ref-type="bibr" rid="bib1.bibx18 bib1.bibx9 bib1.bibx12" id="paren.1"/>. Such NF measurements are usually performed in anechoic chambers, since this echo free measurement environment is an acceptable approximation of free space. However, performing in-situ measurements becomes more relevant as the operation environment of an antenna may influence its performance. Moreover, many relevant antennas cannot be brought into antenna measurement chambers and the interest in portable and flexible antenna measurement solutions is, thus, growing. A key enabler of portable and flexible measurement solutions with irregular measurement locations and measurement probe orientations is the availability of an appropriate NFFFT algorithm, which is able to handle the collected measurement data.
Advanced NFFFT algorithms such as the fast irregular antenna field transformation algorithm (FIAFTA) can perform such tasks and offer even additional diagnostic capabilities <xref ref-type="bibr" rid="bib1.bibx3 bib1.bibx4" id="paren.2"/>.
Another important property of this kind of transformation approach is its capability to consider the measurement environment at least in parts, e.g., by the consideration of a reflective ground half-space, either metallic or even dielectric <xref ref-type="bibr" rid="bib1.bibx11 bib1.bibx2" id="paren.3"/>, or by the direct modelling of scatterers <xref ref-type="bibr" rid="bib1.bibx19" id="paren.4"/>.</p>
      <p id="d1e130">A very sophisticated measurement system for high-quality measurements of antennas in assembly halls by utilizing an overhead crane is described in <xref ref-type="bibr" rid="bib1.bibx8" id="text.5"/>. This system works with a measurement gondola positioned by the overhead crane where the exact position and orientation of the measurement probe is determined by a 6D laser tracking device.</p>
      <p id="d1e136">Another even more flexible approach for the realization of in-situ measurements is the employment of a UAV which carries the probe antenna to the desired positions <xref ref-type="bibr" rid="bib1.bibx6" id="paren.6"/>. First experiments and tests in the field of UAV-based antenna measurements are found in <xref ref-type="bibr" rid="bib1.bibx7" id="text.7"/> and <xref ref-type="bibr" rid="bib1.bibx17" id="text.8"/>. A severe problem with these published approaches is that the used receivers can only measure the magnitudes of the fields. Since available algorithms for phaseless NFFFTs are not yet accurate and reliable enough <xref ref-type="bibr" rid="bib1.bibx13" id="paren.9"/>, the results and error levels are still far from what is achievable with NF measurements performed in anechoic chambers.</p>
      <?pagebreak page18?><p id="d1e151">Sometimes the exact characterization of an antenna in its real environment might not be necessary, since the principle antenna behavior is known and only the influence of the operation environment shall be revealed, e.g., of the mast carrying a radio broadcast antenna or other nearby scattering objects. Another application scenario is the verification of antennas mounted onto a satellite. Satellites are built on construction sites and then shipped thousands of kilometers to a spaceport for take-off to space. In this case, the antenna behavior is known and only the correct operation needs to be verified in a fast check-up because of possible damages due to packaging and transportation.</p>
      <p id="d1e155">In this paper, we present a simple method for the NF measurement of antennas with manual collection of the field samples. Within traditional NF ranges, the probe antenna is commonly mounted on a positioning system which is capable of moving the antenna to a predefined position. Instead of using a sophisticated positioner or a UAV as mentioned before, the probe antenna is moved manually by an operator person. This implies that the position and orientation of the probe antenna are not exactly known from the positioning itself. To cope with this, the position of the probe antenna is measured by a laser tracker. The orientation data is not determined or measured at all and, therefore, introduces some uncertainty into the measurement data. Because of its simplicity, the measurement setup is very flexible for transportation and can be used for fast on-site testing of antennas.</p>
      <p id="d1e158">The basic arrangement of such a measurement system was already described in <xref ref-type="bibr" rid="bib1.bibx1" id="text.10"/>. A similar system  with manual movement of the field probe has recently been published in <xref ref-type="bibr" rid="bib1.bibx10" id="text.11"/> for field monitoring and for radar applications in <xref ref-type="bibr" rid="bib1.bibx20" id="text.12"/>. The main difference to the system in this paper is the employed positioning system. In <xref ref-type="bibr" rid="bib1.bibx10" id="text.13"/> and <xref ref-type="bibr" rid="bib1.bibx20" id="text.14"/>, an optical tracking system was employed while our system is based on a laser tracker. On the one hand, the optical tracking system provides orientation data of the probe while the laser tracker does not. On the other hand, the laser tracker is much more more flexible in terms of operation range and area while an optical tracking system has a limited range and is more applicable for indoor operation.</p>
      <p id="d1e176">This paper is structured as follows. Section <xref ref-type="sec" rid="Ch1.S2"/> describes the setup and hardware implementation of the measurement system. Measurement results for two different scanning geometries, quasi-planar and quasi-cylindrical, are presented in Sect. <xref ref-type="sec" rid="Ch1.S3"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><?xmltex \currentcnt{1}?><label>Figure 1</label><caption><p id="d1e185">Schematic drawing of the measurement setup. The field and position data of the manually moved probe antenna are recorded by a vector network analyzer (VNA) and a laser tracker, respectively. The probe antenna is connected by an optical fiber link to the VNA and a Raspberry Pi (RPi) is used to read and store the data from the VNA and laser tracker.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020-f01.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><?xmltex \currentcnt{2}?><label>Figure 2</label><caption><p id="d1e196">The Vivaldi probe antenna is attached to a handle which carries the retro-reflector target (SMR), the RF-over-fiber converter and a battery.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020-f02.png"/>

      </fig>

</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Setup and implementation</title>
      <p id="d1e213">A schematic drawing of the measurement setup is shown in Fig. <xref ref-type="fig" rid="Ch1.F1"/>.
The two main components are a laser tracker of model FARO Vantage <xref ref-type="bibr" rid="bib1.bibx5" id="paren.15"/> and a vector network analyzer (VNA) of type R&amp;S ZVL <xref ref-type="bibr" rid="bib1.bibx15" id="paren.16"/>. The laser tracker is capable of measuring the position of a spherical-mounted retro-reflector (SMR) up to sub-millimeter accuracy. The SMR is attached to the bottom of the utilized probe antenna handle. The network analyzer is connected to the antenna under test (AUT) and the probe antenna, so that the complex transmission parameter can be recorded during the measurement. While the AUT is connected to the VNA via an SMA-cable, which exhibits an attenuation of <inline-formula><mml:math id="M1" display="inline"><mml:mn mathvariant="normal">4.45</mml:mn></mml:math></inline-formula> dB at <inline-formula><mml:math id="M2" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> GHz, the probe antenna is connected to the VNA by an optical fiber link. For this, an RF-over-fiber module <xref ref-type="bibr" rid="bib1.bibx16" id="paren.17"/> is mounted on the probe handle together with a battery as power supply for the RF-over-fiber module. Despite its attenuation of <inline-formula><mml:math id="M3" display="inline"><mml:mn mathvariant="normal">4.83</mml:mn></mml:math></inline-formula> dB, the advantage of the optical fiber link<?pagebreak page19?> over an SMA-cable is the flexibility of the probe handle and it also diminishes the influence of possible cable bending due to the movement of the probe. In particular, the phase stability of the optical fiber link has been found to be very good and the attenuation of the optical fiber link is also low with about <inline-formula><mml:math id="M4" display="inline"><mml:mn mathvariant="normal">0.05</mml:mn></mml:math></inline-formula> dB at 1 GHz. However, it must be kept in mind that the noise figure of the optical fiber link is on the order of 15 to 20 dB. Both, laser tracker and VNA are triggered from a Raspberry Pi (RPi). After each trigger impulse, the data from both devices are read out and stored before a new trigger impulse is sent, in order to ensure that the field and position data correspond to each other. The utilized measurement probe is a PCB fabricated Vivaldi antenna working in the frequency range of 1 to 3 GHz and as seen in Fig. <xref ref-type="fig" rid="Ch1.F2"/>.
Its radiation behaviour, when it is mounted on the probe handle together with the RF-over-fiber converter and the battery, has been measured in the anechoic chamber at the Technical University of Munich and validated by simulation. An illustration of the measured probe pattern is found in Fig. <xref ref-type="fig" rid="Ch1.F3"/>.</p>

      <fig id="Ch1.F3"><?xmltex \currentcnt{3}?><label>Figure 3</label><caption><p id="d1e261">Far-field radiation pattern of the probe antenna including the handle and all electronics. The pattern has been measured in an anechoic chamber.</p></caption>
        <?xmltex \igopts{width=128.037402pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020-f03.png"/>

      </fig>

</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Measurement results</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Planar measurement geometry</title>
      <p id="d1e285">The described setup has been tested in a large sports facility.
Figure <xref ref-type="fig" rid="Ch1.F4"/> shows the setup where the double-ridged horn antenna DRH400 was used as AUT, mounted on a stand <inline-formula><mml:math id="M5" display="inline"><mml:mn mathvariant="normal">2.4</mml:mn></mml:math></inline-formula> m above ground. The measurement frequency was <inline-formula><mml:math id="M6" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> GHz while a set of position and field data was recorded every 50 ms. The AUT near-field was scanned on an almost planar surface in horizontal lines as depicted in Fig. <xref ref-type="fig" rid="Ch1.F5"/>.</p>

      <fig id="Ch1.F4"><?xmltex \currentcnt{4}?><label>Figure 4</label><caption><p id="d1e307">On-site measurement scenario. An operator person moves the probe antenna on a planar scanning surface in front of the antenna under test. The probe position is tracked by a laser tracker, while the probe antenna itself is connected to a vector network analyzer by an optical fiber link.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020-f04.png"/>

        </fig>

      <fig id="Ch1.F5"><?xmltex \currentcnt{5}?><label>Figure 5</label><caption><p id="d1e317">Magnitudes of the near-field samples located on the quasi-planar measurement surface. Each dot represents one measurement sample where the field magnitude is coded in color.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020-f05.png"/>

        </fig>

      <p id="d1e326">The main beam of the AUT can clearly be seen within the NF data. However, there are fluctuations in the field magnitude which is due to improper orientation of the probe antenna and noise due to parasitic echo contributions and external interference. An operator person carried the probe antenna during the measurements, where a long wooden stick extended the positioning range to larger heights above ground at the risk of a less accurate probe orientation. During the NFFFT via FIAFTA, it was assumed that the probe orientation did not change during the whole measurement data acquisition. Obviously, this introduces some errors into the field transformation since the correction of the probe influence on the measured field data cannot be fully corrected due to possibly wrong orientation data of the probe antenna. The probe correction is performed utilizing the FF pattern of the Vivaldi antenna including the handle and all electronics, as shown in Fig. <xref ref-type="fig" rid="Ch1.F3"/>.
In most parts of the scan area, the sampling of the NF is considerably finer than required by the sampling theorem. This was desired as it reduces the error influence of single measurement samples. A comparison of the resulting FF pattern with a reference measurement, performed in the anechoic chamber of the Technical University of Munich, reveals a deviation of up to <inline-formula><mml:math id="M7" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula> dB within the expected valid angular range. The FF main cuts for <inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">90</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> are depicted in Fig. <xref ref-type="fig" rid="Ch1.F6"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><?xmltex \currentcnt{6}?><label>Figure 6</label><caption><p id="d1e378">Far-field main cuts in the valid angles with and without ground consideration. The phi-cut <bold>(a)</bold> is evaluated at <inline-formula><mml:math id="M10" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">90</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and the theta-cut <bold>(b)</bold> at <inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. The maximum deviation of the measurement from the reference is <inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula> dB.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020-f06.png"/>

        </fig>

      <?pagebreak page20?><p id="d1e435">The deviation between the manual measurements and the reference is given by
            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M13" display="block"><mml:mrow><mml:mi mathvariant="italic">ϵ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">20</mml:mn><mml:mi>log⁡</mml:mi><mml:mfenced open="|" close="|"><mml:mrow><mml:mfenced close="|" open="|"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mo>max⁡</mml:mo><mml:mfenced open="(" close=")"><mml:mfenced close="|" open="|"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>-</mml:mo><mml:mfenced open="|" close="|"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">man</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mo>max⁡</mml:mo><mml:mfenced close=")" open="("><mml:mfenced close="|" open="|"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">man</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mfenced></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M14" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">ref</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the FF of the reference measurement and <inline-formula><mml:math id="M15" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mi mathvariant="normal">man</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the FF of the manual measurement. Due to the finite scan surface, the transformation results are only valid in a certain angular range. The valid angles are calculated according to
<?xmltex \hack{\newpage}?><?xmltex \hack{\vspace*{-6mm}}?>
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M16" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mi mathvariant="normal">valid</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mi mathvariant="normal">tan</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>x</mml:mi><mml:mi mathvariant="normal">meas</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>w</mml:mi><mml:mi mathvariant="normal">aut</mml:mi></mml:msub></mml:mrow><mml:mi>d</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced></mml:mrow></mml:math></disp-formula>
          and
            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M17" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">θ</mml:mi><mml:mi mathvariant="normal">valid</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mi mathvariant="normal">tan</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mfenced close=")" open="("><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>y</mml:mi><mml:mi mathvariant="normal">meas</mml:mi></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi>h</mml:mi><mml:mi mathvariant="normal">aut</mml:mi></mml:msub></mml:mrow><mml:mi>d</mml:mi></mml:mfrac></mml:mstyle></mml:mfenced><mml:mspace width="0.33em" linebreak="nobreak"/><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M18" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>x</mml:mi><mml:mi mathvariant="normal">meas</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M19" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msub><mml:mi>y</mml:mi><mml:mi mathvariant="normal">meas</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> are the width and length of the measurement surface and <inline-formula><mml:math id="M20" display="inline"><mml:mrow><mml:msub><mml:mi>w</mml:mi><mml:mi mathvariant="normal">aut</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M21" display="inline"><mml:mrow><mml:msub><mml:mi>h</mml:mi><mml:mi mathvariant="normal">aut</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> the width and height of the AUT. The finite scan surface also introduces errors within the valid angular range, especially near the edges, as, e.g., also described in <xref ref-type="bibr" rid="bib1.bibx14" id="text.18"/>.</p>
      <p id="d1e660">On-site antenna measurements are inherently different from NF measurements performed in anechoic chambers in terms of external influences such as scatterers and ground effects. Therefore, these influences should be taken into account within the NFFFT. The measurement has been performed in a large sports facility to ensure free space around the AUT and lower the influence of scatters. Figure <xref ref-type="fig" rid="Ch1.F6"/> also includes the results of the NFFFT performed with consideration of dielectric ground. A comparison of the FF cuts with and without ground consideration reveals that the ground influence is little in this measurement.  In fact, this quasi-planar measurement has been performed several times with similar results in terms of error level and ground influence. The errors of some measurements are given in Table <xref ref-type="table" rid="Ch1.T1"/>, which shows the repeatability of such manual antenna measurements within the stated error bounds.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e670">Comparison of the far-field errors of multiple quasi-planar measurements. Meas 1 is the measurement described in detail in Sect. <xref ref-type="sec" rid="Ch1.S3.SS1"/>, while all other measurements have been performed in a similar manner. Note that the frequency of Meas 4 is different from the others.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:thead>
       <oasis:row>

         <oasis:entry colname="col1"/>

         <oasis:entry rowsep="1" colname="col2" morerows="1">frequency</oasis:entry>

         <oasis:entry rowsep="1" namest="col3" nameend="col4" align="center">max. far-field error </oasis:entry>

       </oasis:row>
       <oasis:row rowsep="1">

         <oasis:entry colname="col1"/>

         <oasis:entry colname="col3">phi-cut (<inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">90</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>

         <oasis:entry colname="col4">theta-cut (<inline-formula><mml:math id="M23" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>)</oasis:entry>

       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>

         <oasis:entry colname="col1">Meas 1</oasis:entry>

         <oasis:entry colname="col2">1 GHz</oasis:entry>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M24" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">22.29</mml:mn></mml:mrow></mml:math></inline-formula> dB</oasis:entry>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M25" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">20.18</mml:mn></mml:mrow></mml:math></inline-formula> dB</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1">Meas 2</oasis:entry>

         <oasis:entry colname="col2">1 GHz</oasis:entry>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">22.51</mml:mn></mml:mrow></mml:math></inline-formula> dB</oasis:entry>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">17.06</mml:mn></mml:mrow></mml:math></inline-formula> dB</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1">Meas 3</oasis:entry>

         <oasis:entry colname="col2">1 GHz</oasis:entry>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">24.37</mml:mn></mml:mrow></mml:math></inline-formula> dB</oasis:entry>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">20.36</mml:mn></mml:mrow></mml:math></inline-formula> dB</oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry colname="col1">Meas 4</oasis:entry>

         <oasis:entry colname="col2">2.4 GHz</oasis:entry>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">24.33</mml:mn></mml:mrow></mml:math></inline-formula> dB</oasis:entry>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M31" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">17.28</mml:mn></mml:mrow></mml:math></inline-formula> dB</oasis:entry>

       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><?xmltex \currentcnt{7}?><label>Figure 7</label><caption><p id="d1e883">The laser tracker was placed under the AUT <bold>(a)</bold> to perform a manual measurement with a cylindrical scan geometry. In the NFFFT, an AUT mesh (yellow) was used for the computation of the far-field while a mesh of the laser tracker (copper) was declared as scatterer <bold>(b)</bold>.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020-f07.jpg"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Cylindrical measurement geometry</title>
      <?pagebreak page21?><p id="d1e906">To increase the valid angular range in horizontal direction, another measurement with a cylindrical scan geometry has been performed. For this, the laser tracker was placed under the AUT as depicted in Fig. <xref ref-type="fig" rid="Ch1.F7"/>a. This was necessary since line-of-sight between the laser tracker and the SMR is required and could otherwise not be realized for all measurement positions.
Again, the probe antenna handle was moved by an operator person with the extension of a wooden stick in the upper field parts. The AUT itself was placed 2 m above ground and the vertical distance between AUT and laser tracker was 30 cm. Once more, the field has been measured at a frequency of 1 GHz while the recording interval was decreased to 5 ms to collect even more samples. Figure <xref ref-type="fig" rid="Ch1.F8"/> shows the magnitude of the measured field data.
The transformed FF cuts are shown in Fig. <xref ref-type="fig" rid="Ch1.F9"/>. A comparison of Figs. <xref ref-type="fig" rid="Ch1.F6"/>a and <xref ref-type="fig" rid="Ch1.F9"/>a reveals that the valid angular range could be increased with a similar error level of the results.</p>

      <fig id="Ch1.F8"><?xmltex \currentcnt{8}?><label>Figure 8</label><caption><p id="d1e920">Magnitude of the measured near-field where red represents high and blue low magnitude. The field has been measured on a cylindrical scan geometry to increase the valid angles.</p></caption>
          <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020-f08.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9"><?xmltex \currentcnt{9}?><label>Figure 9</label><caption><p id="d1e931">Far-field main cuts in the valid angular range for <inline-formula><mml:math id="M32" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">90</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> <bold>(a)</bold> and <inline-formula><mml:math id="M33" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> <bold>(b)</bold>. The transformation results are shown with and without the consideration of the laser tracker as an echo source.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/17/2020/ars-18-17-2020-f09.png"/>

        </fig>

      <p id="d1e979">Due to the close vicinity between AUT and laser tracker, some influence on the measured field in terms of scattered field contributions from the laser tracker is expected and should be considered in the NFFFT. For this, the laser tracker was modeled and included into the mesh file as depicted in Fig. <xref ref-type="fig" rid="Ch1.F7"/>b. The employed NFFFT algorithm, FIAFTA, computes the equivalent currents on the whole mesh while eventually only the AUT currents are used for the computation of the FF. The FF cuts in Fig. <xref ref-type="fig" rid="Ch1.F9"/> show the transformation results with and without the modelling of the laser tracker as echo source. It can be seen that the error level is reduced in Fig. <xref ref-type="fig" rid="Ch1.F9"/>b when the laser tracker is considered.</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusion</title>
      <p id="d1e997">A simple NF measurement setup for on-site testing of antennas has been presented. The operation performance was shown by two near-field measurements that have been transformed into the far-field by near-field far-field transformation. Even if the error level is higher in comparison with traditional near-field measurements in anechoic chambers, the system performs well for the principle validation of antennas. It was further shown that the measurement system is very powerful in particular in combination with appropriate near-field far-field transformation algorithms, which enable the consideration of ground effects and echo sources. The clear advantage of this setup over traditional near-field ranges is its mobility and flexibility that enables on-site antenna testing.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e1005">The underlying research data can be requested from the authors.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e1011">FTF, TFE and HJS worked out the concept of the measurement system. FTF built the setup and carried out the measurements. TFE supervised the measurements and helped with the post-processing of the data. All authors read and approved the final manuscript.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e1017">The authors declare that they have no conflict of interest.</p>
  </notes><notes notes-type="sistatement"><title>Special issue statement</title>

      <p id="d1e1023">This article is part of the special issue “Kleinheubacher Berichte 2019”. It is a result of the Kleinheubacher Tagung 2019, Miltenberg, Germany, 23–25 September 2019.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e1029">The authors thank   Thomas Mittereder for his help during the on-site measurements.</p></ack><?xmltex \hack{\newpage}?><?xmltex \hack{\newpage}?><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e1035">This work was supported by the German Federal Ministry for Economic Affairs and Energy (grant no. 20E1711A).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e1041">This paper was edited by Romanus Dyczij-Edlinger and reviewed by Heyno Garbe and Adrian Amor-Martin.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Eibert et al.(2013)Eibert, Fritzel, Schmidt, and
Steiner</label><?label art_Eibert2013?><mixed-citation>
Eibert, T., Fritzel, T., Schmidt, C., and Steiner, H.-J.: Method and device for
measuring a radiation field, United States Patent No., US8 410 987 B2,
2013.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Eibert and Mauermayer(2018)</label><?label art_Eibert2018?><mixed-citation>
Eibert, T. F. and Mauermayer, R. A. M.: Equivalent sources based near-field
far-field transformation above dielectric half space, in: Proc. 40th Annual
Meeting and Symposium of the Antenna Measurement Techniques Association
(AMTA), Williamsburg, VA, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>Eibert et al.(2010)Eibert, Ismatullah, Kaliyaperumal, and
Schmidt</label><?label art_Eibert2010?><mixed-citation>Eibert, T. F., Ismatullah, Kaliyaperumal, E., and Schmidt, C. H.: Inverse
equivalent surface current method with hierarchical higher order basis
functions, full probe correction and multilevel fast multipole acceleration
(invited paper), Prog. Electromagn. Res., 106, 377–394,
<ext-link xlink:href="https://doi.org/10.2528/PIER10061604" ext-link-type="DOI">10.2528/PIER10061604</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Eibert et al.(2015)Eibert, Kilic, Lopez, Mauermayer, Neitz, and
Schnattinger</label><?label art_Eibert2015?><mixed-citation>Eibert, T. F., Kilic, E., Lopez, C., Mauermayer, R. A. M., Neitz, O., and
Schnattinger, G.: Electromagnetic field transformations for measurements and
simulations (invited paper), Prog. Electromagn. Res., 151,
127–150, <ext-link xlink:href="https://doi.org/10.2528/PIER14121105" ext-link-type="DOI">10.2528/PIER14121105</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>FARO Technologies Inc.(2016)</label><?label man_farovantage?><mixed-citation>
FARO Technologies Inc.: FARO Laser Tracker Vantage Benutzerhandbuch, Rev. D, April 2016 (in German).</mixed-citation></ref>
      <ref id="bib1.bibx6"><label>Fritzel et al.(2016)Fritzel, Strauß, Steiner, Eisner, and
Eibert</label><?label art_Fritzel2016?><mixed-citation>Fritzel, T., Strauß, R., Steiner, H., Eisner, C., and Eibert, T. F.:
Introduction into an UAV-based near-field system for in-situ and
large-scale antenna measurements (invited paper), in: Proc. IEEE Conference
on Antenna Measurements Applications (CAMA), Syracuse, NY,
<ext-link xlink:href="https://doi.org/10.1109/CAMA.2016.7815762" ext-link-type="DOI">10.1109/CAMA.2016.7815762</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>García-Fernández et al.(2017)García-Fernández, Álvarez López,
Arboleya, González-Valdés, Rodríguez-Vaqueiro, Gómez, and
Andrés</label><?label art_Garcia-Fernandez2017?><mixed-citation>García-Fernández, M., Álvarez López, Y., Arboleya, A., González-Valdés,
B., Rodríguez-Vaqueiro, Y., Gómez, M. E. D. C., and Andrés, F. L.-H.:
Antenna diagnostics and characterization using unmanned aerial vehicles, IEEE
Access, 5, 23563–23575, <ext-link xlink:href="https://doi.org/10.1109/ACCESS.2017.2754985" ext-link-type="DOI">10.1109/ACCESS.2017.2754985</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Geise et al.(2019)Geise, Neitz, Migl, Steiner, Fritzel, Hunscher, and
Eibert</label><?label art_Geise2019?><mixed-citation>Geise, A., Neitz, O., Migl, J., Steiner, H.-J., Fritzel, T., Hunscher, C., and
Eibert, T. F.: A crane based portable antenna measurement system – system
description and validation, IEEE T. Antenn. Propag.,
67, 3346–3357, <ext-link xlink:href="https://doi.org/10.1109/TAP.2019.2900373" ext-link-type="DOI">10.1109/TAP.2019.2900373</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Gregson et al.(2007)Gregson, McCormick, and
Parini</label><?label book_Gregson2007?><mixed-citation>Gregson, S., McCormick, J., and Parini, C.: Principles of Planar Near-field
Antenna Measurements, IET, MPG Books Ltd., Bodmin, Cornwall, 2007.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bibx10"><label>He et al.(2016)He, Maheshwari, and Pommerenke</label><?label art_He2016?><mixed-citation>He, H., Maheshwari, P., and Pommerenke, D. J.: The development of an
EM-field probing system for manual near-field scanning, IEEE T.
Electromagn. C., 58, 356–363,
<ext-link xlink:href="https://doi.org/10.1109/TEMC.2015.2496376" ext-link-type="DOI">10.1109/TEMC.2015.2496376</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Mauermayer and Eibert(2016)</label><?label art_Mauermayer2016b?><mixed-citation>Mauermayer, R. A. M. and Eibert, T. F.: Fast irregular antenna field
transformation above perfectly conducting ground planes, in: European
Conference on Antennas and Propagation (EUCAP), Davos, Switzerland,
<ext-link xlink:href="https://doi.org/10.1109/EuCAP.2016.7481231" ext-link-type="DOI">10.1109/EuCAP.2016.7481231</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>Parini et al.(2014)Parini, Gregson, McCormick, and
Rensburg</label><?label book_Parini2014?><mixed-citation>
Parini, C., Gregson, S. F., McCormick, J., and Rensburg, D. J. V.: Theory and
Practice of Modern Antenna Range Measurements, The Institution of Engineering
and Technology, London, UK, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Paulus et al.(2017)Paulus, Knapp, and Eibert</label><?label art_Paulus2017?><mixed-citation>Paulus, A., Knapp, J., and Eibert, T. F.: Phaseless near-field far-field
transformation utilizing combinations of probe signals, IEEE T.
Antennas  Prop., 65, 5492–5502, <ext-link xlink:href="https://doi.org/10.1109/TAP.2017.2735463" ext-link-type="DOI">10.1109/TAP.2017.2735463</ext-link>,
2017.</mixed-citation></ref>
      <ref id="bib1.bibx14"><label>Qureshi(2013)</label><?label phd_Qureshi2013?><mixed-citation>
Qureshi, M. A.: Near-Field Error Analysis and Efficient Sampling Techniques for
the Fast Irregular Antenna Field Transformation Algorithm, Doctoral
Dissertation,Technische Universität München, Fakultät fur Elektrotechnik
und Informationstechnik, Munich, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx15"><?xmltex \def\ref@label{{{Rohde {\&} Schwarz}(2020)}}?><label>Rohde &amp; Schwarz(2020)</label><?label www_rszvl?><mixed-citation>Rohde &amp; Schwarz: R&amp;S ZVL Vector Network Analyzers,
available at:  <uri>https://www.rohde-schwarz.com/de/produkt/zvl-produkt-startseite_63493-9014.html</uri>, last
access:  17 January 2020.</mixed-citation></ref>
      <ref id="bib1.bibx16"><label>ViaLite Communications(2020)</label><?label man_vialiterf?><mixed-citation>ViaLite Communications: ViaLiteHD Fibre Optic Link User Guide, version 2017, available at: <uri>https://www.vialite.com/wp-content/uploads/2017/10/ViaLiteHD-RF-Link-Handbook-HRx-HB-7.pdf</uri>, last access: 17 January 2020.</mixed-citation></ref>
      <ref id="bib1.bibx17"><label>Virone et al.(2014)Virone, Lingua, Piras, Cina, Perini, Monari,
Paonessa, Peverini, Addamo, and Tascone</label><?label art_Virone2014?><mixed-citation>Virone, G., Lingua, A. M., Piras, M., Cina, A., Perini, F., Monari, J.,
Paonessa, F., Peverini, O. A., Addamo, G., and Tascone, R.: Antenna pattern
verification system based on a micro unmanned aerial vehicle (UAV), IEEE
Antenn. Wirel. Pr., 13, 169–172,
<ext-link xlink:href="https://doi.org/10.1109/LAWP.2014.2298250" ext-link-type="DOI">10.1109/LAWP.2014.2298250</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx18"><label>Yaghjian(1986)</label><?label art_Yaghjian1986?><mixed-citation>Yaghjian, A.: An overview of near-field antenna measurements, IEEE
T. Antenn. Propag., 34, 30–45,
<ext-link xlink:href="https://doi.org/10.1109/tap.1986.1143727" ext-link-type="DOI">10.1109/tap.1986.1143727</ext-link>, 1986.</mixed-citation></ref>
      <ref id="bib1.bibx19"><label>Yinusa et al.(2012)Yinusa, Schmidt, and Eibert</label><?label art_Yinusa2012?><mixed-citation>Yinusa, K. A., Schmidt, C. H., and Eibert, T. F.: Modeling of unknown echoic
measurement facilities with equivalent scattering centers, in: European
Conference on Antennas and Propagation (EUCAP), Prague, Czech
Republic, 2104–2108, <ext-link xlink:href="https://doi.org/10.1109/EuCAP.2012.6205875" ext-link-type="DOI">10.1109/EuCAP.2012.6205875</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx20"><label>Álvarez-Narciandi et al.(2019)Álvarez-Narciandi,
López-Portugués, Las-Heras, and Laviada</label><?label art_Alvarez2019?><mixed-citation>Álvarez-Narciandi, G., López-Portugués, M., Las-Heras, F., and
Laviada, J.: Freehand, agile, and high-resolution imaging with compact
mm-wave radar, IEEE Access, 7, 95516–95526,
<ext-link xlink:href="https://doi.org/10.1109/ACCESS.2019.2929522" ext-link-type="DOI">10.1109/ACCESS.2019.2929522</ext-link>, 2019.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Near-Field Antenna Measurements with Manual Collection of the Measurement Samples</article-title-html>
<abstract-html><p>Near-field measurements are commonly performed in anechoic chambers which limits the flexibility of the measurements and requires high precision equipment to achieve exact results. In this contribution, we investigate a simple near-field measurement setup which does not use any sophisticated positioning system nor operates in a controlled environment. Instead, the probe antenna is moved by an operator person while the probe position is measured by a laser tracker. This implies that the measurement results will have a higher error level in comparison with antenna chamber measurements. However, excellent error levels are not always necessary, especially when it comes to on-site testing of the principle functionality of antennas. Measurement results are shown to illustrate the performance of the system.</p></abstract-html>
<ref-html id="bib1.bib1"><label>Eibert et al.(2013)Eibert, Fritzel, Schmidt, and
Steiner</label><mixed-citation>
Eibert, T., Fritzel, T., Schmidt, C., and Steiner, H.-J.: Method and device for
measuring a radiation field, United States Patent No., US8&thinsp;410&thinsp;987&thinsp;B2,
2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Eibert and Mauermayer(2018)</label><mixed-citation>
Eibert, T. F. and Mauermayer, R. A. M.: Equivalent sources based near-field
far-field transformation above dielectric half space, in: Proc. 40th Annual
Meeting and Symposium of the Antenna Measurement Techniques Association
(AMTA), Williamsburg, VA, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Eibert et al.(2010)Eibert, Ismatullah, Kaliyaperumal, and
Schmidt</label><mixed-citation>
Eibert, T. F., Ismatullah, Kaliyaperumal, E., and Schmidt, C. H.: Inverse
equivalent surface current method with hierarchical higher order basis
functions, full probe correction and multilevel fast multipole acceleration
(invited paper), Prog. Electromagn. Res., 106, 377–394,
<a href="https://doi.org/10.2528/PIER10061604" target="_blank">https://doi.org/10.2528/PIER10061604</a>, 2010.
</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Eibert et al.(2015)Eibert, Kilic, Lopez, Mauermayer, Neitz, and
Schnattinger</label><mixed-citation>
Eibert, T. F., Kilic, E., Lopez, C., Mauermayer, R. A. M., Neitz, O., and
Schnattinger, G.: Electromagnetic field transformations for measurements and
simulations (invited paper), Prog. Electromagn. Res., 151,
127–150, <a href="https://doi.org/10.2528/PIER14121105" target="_blank">https://doi.org/10.2528/PIER14121105</a>, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>FARO Technologies Inc.(2016)</label><mixed-citation>
FARO Technologies Inc.: FARO Laser Tracker Vantage Benutzerhandbuch, Rev. D, April 2016 (in German).
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Fritzel et al.(2016)Fritzel, Strauß, Steiner, Eisner, and
Eibert</label><mixed-citation>
Fritzel, T., Strauß, R., Steiner, H., Eisner, C., and Eibert, T. F.:
Introduction into an UAV-based near-field system for in-situ and
large-scale antenna measurements (invited paper), in: Proc. IEEE Conference
on Antenna Measurements Applications (CAMA), Syracuse, NY,
<a href="https://doi.org/10.1109/CAMA.2016.7815762" target="_blank">https://doi.org/10.1109/CAMA.2016.7815762</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>García-Fernández et al.(2017)García-Fernández, Álvarez López,
Arboleya, González-Valdés, Rodríguez-Vaqueiro, Gómez, and
Andrés</label><mixed-citation>
García-Fernández, M., Álvarez López, Y., Arboleya, A., González-Valdés,
B., Rodríguez-Vaqueiro, Y., Gómez, M. E. D. C., and Andrés, F. L.-H.:
Antenna diagnostics and characterization using unmanned aerial vehicles, IEEE
Access, 5, 23563–23575, <a href="https://doi.org/10.1109/ACCESS.2017.2754985" target="_blank">https://doi.org/10.1109/ACCESS.2017.2754985</a>, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Geise et al.(2019)Geise, Neitz, Migl, Steiner, Fritzel, Hunscher, and
Eibert</label><mixed-citation>
Geise, A., Neitz, O., Migl, J., Steiner, H.-J., Fritzel, T., Hunscher, C., and
Eibert, T. F.: A crane based portable antenna measurement system – system
description and validation, IEEE T. Antenn. Propag.,
67, 3346–3357, <a href="https://doi.org/10.1109/TAP.2019.2900373" target="_blank">https://doi.org/10.1109/TAP.2019.2900373</a>, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Gregson et al.(2007)Gregson, McCormick, and
Parini</label><mixed-citation>
Gregson, S., McCormick, J., and Parini, C.: Principles of Planar Near-field
Antenna Measurements, IET, MPG Books Ltd., Bodmin, Cornwall, 2007.

</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>He et al.(2016)He, Maheshwari, and Pommerenke</label><mixed-citation>
He, H., Maheshwari, P., and Pommerenke, D. J.: The development of an
EM-field probing system for manual near-field scanning, IEEE T.
Electromagn. C., 58, 356–363,
<a href="https://doi.org/10.1109/TEMC.2015.2496376" target="_blank">https://doi.org/10.1109/TEMC.2015.2496376</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Mauermayer and Eibert(2016)</label><mixed-citation>
Mauermayer, R. A. M. and Eibert, T. F.: Fast irregular antenna field
transformation above perfectly conducting ground planes, in: European
Conference on Antennas and Propagation (EUCAP), Davos, Switzerland,
<a href="https://doi.org/10.1109/EuCAP.2016.7481231" target="_blank">https://doi.org/10.1109/EuCAP.2016.7481231</a>, 2016.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Parini et al.(2014)Parini, Gregson, McCormick, and
Rensburg</label><mixed-citation>
Parini, C., Gregson, S. F., McCormick, J., and Rensburg, D. J. V.: Theory and
Practice of Modern Antenna Range Measurements, The Institution of Engineering
and Technology, London, UK, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Paulus et al.(2017)Paulus, Knapp, and Eibert</label><mixed-citation>
Paulus, A., Knapp, J., and Eibert, T. F.: Phaseless near-field far-field
transformation utilizing combinations of probe signals, IEEE T.
Antennas  Prop., 65, 5492–5502, <a href="https://doi.org/10.1109/TAP.2017.2735463" target="_blank">https://doi.org/10.1109/TAP.2017.2735463</a>,
2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Qureshi(2013)</label><mixed-citation>
Qureshi, M. A.: Near-Field Error Analysis and Efficient Sampling Techniques for
the Fast Irregular Antenna Field Transformation Algorithm, Doctoral
Dissertation,Technische Universität München, Fakultät fur Elektrotechnik
und Informationstechnik, Munich, 2013.
</mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Rohde &amp; Schwarz(2020)</label><mixed-citation>
Rohde &amp; Schwarz: R&amp;S ZVL Vector Network Analyzers,
available at:  <a href="https://www.rohde-schwarz.com/de/produkt/zvl-produkt-startseite_63493-9014.html" target="_blank"/>, last
access:  17 January 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>ViaLite Communications(2020)</label><mixed-citation>
ViaLite Communications: ViaLiteHD Fibre Optic Link User Guide, version 2017, available at: <a href="https://www.vialite.com/wp-content/uploads/2017/10/ViaLiteHD-RF-Link-Handbook-HRx-HB-7.pdf" target="_blank"/>, last access: 17 January 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Virone et al.(2014)Virone, Lingua, Piras, Cina, Perini, Monari,
Paonessa, Peverini, Addamo, and Tascone</label><mixed-citation>
Virone, G., Lingua, A. M., Piras, M., Cina, A., Perini, F., Monari, J.,
Paonessa, F., Peverini, O. A., Addamo, G., and Tascone, R.: Antenna pattern
verification system based on a micro unmanned aerial vehicle (UAV), IEEE
Antenn. Wirel. Pr., 13, 169–172,
<a href="https://doi.org/10.1109/LAWP.2014.2298250" target="_blank">https://doi.org/10.1109/LAWP.2014.2298250</a>, 2014.
</mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Yaghjian(1986)</label><mixed-citation>
Yaghjian, A.: An overview of near-field antenna measurements, IEEE
T. Antenn. Propag., 34, 30–45,
<a href="https://doi.org/10.1109/tap.1986.1143727" target="_blank">https://doi.org/10.1109/tap.1986.1143727</a>, 1986.
</mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>Yinusa et al.(2012)Yinusa, Schmidt, and Eibert</label><mixed-citation>
Yinusa, K. A., Schmidt, C. H., and Eibert, T. F.: Modeling of unknown echoic
measurement facilities with equivalent scattering centers, in: European
Conference on Antennas and Propagation (EUCAP), Prague, Czech
Republic, 2104–2108, <a href="https://doi.org/10.1109/EuCAP.2012.6205875" target="_blank">https://doi.org/10.1109/EuCAP.2012.6205875</a>, 2012.
</mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Álvarez-Narciandi et al.(2019)Álvarez-Narciandi,
López-Portugués, Las-Heras, and Laviada</label><mixed-citation>
Álvarez-Narciandi, G., López-Portugués, M., Las-Heras, F., and
Laviada, J.: Freehand, agile, and high-resolution imaging with compact
mm-wave radar, IEEE Access, 7, 95516–95526,
<a href="https://doi.org/10.1109/ACCESS.2019.2929522" target="_blank">https://doi.org/10.1109/ACCESS.2019.2929522</a>, 2019.
</mixed-citation></ref-html>--></article>
