<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">ARS</journal-id><journal-title-group>
    <journal-title>Advances in Radio Science</journal-title>
    <abbrev-journal-title abbrev-type="publisher">ARS</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Adv. Radio Sci.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1684-9973</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/ars-18-97-2020</article-id><title-group><article-title>Radar system with dedicated planar traveling wave antennas for elderly people monitoring</article-title><alt-title>Radar System for Elderly People Monitoring</alt-title>
      </title-group><?xmltex \runningtitle{Radar System for Elderly People Monitoring}?><?xmltex \runningauthor{S. Schäfer et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <name><surname>Schäfer</surname><given-names>Sassan</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Müller</surname><given-names>Simon</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Schmiech</surname><given-names>Daniel</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Diewald</surname><given-names>Andreas R.</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-5820-109X</ext-link></contrib>
        <aff id="aff1"><institution>Laboratory of Radar Technology and Optical Systems, Hochschule Trier, Schneidershof, 54293 Trier, Germany</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Andreas Diewald (diewald@hochschule-trier.de)</corresp></author-notes><pub-date><day>10</day><month>December</month><year>2020</year></pub-date>
      
      <volume>18</volume>
      <fpage>97</fpage><lpage>110</lpage>
      <history>
        <date date-type="received"><day>1</day><month>March</month><year>2020</year></date>
           <date date-type="rev-recd"><day>17</day><month>June</month><year>2020</year></date>
           <date date-type="accepted"><day>31</day><month>July</month><year>2020</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2020 Sassan Schäfer et al.</copyright-statement>
        <copyright-year>2020</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020.html">This article is available from https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020.html</self-uri><self-uri xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020.pdf">The full text article is available as a PDF file from https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020.pdf</self-uri>
      <abstract><title>Abstract</title>
    <p id="d1e100">Radar systems for contactless vital sign monitoring are well known and an actual object of research.
These radar-based sensors could be used for monitoring of elderly people in their homes but also for detecting the activity of prisoners and to control electrical devices (light, audio, etc.) in smart living environments.
Mostly these sensors are foreseen to be mounted on the ceiling in the middle of a room.
In retirement homes the rooms are mostly rectangular and of standardized size.
Furniture like beds and seating are found at the borders or the corners of the room.
As the propagation path from the center of the room ceiling to the borders and corners of a room is 1.4 and 1.7 time longer the power reflected by people located there is 6 or even 10 dB lower than if located in the center of the room.
Furthermore classical antennas in microstrip technology are strengthening radiation in broadside direction.
Radar systems with only one single planar antenna must be mounted horizontally aligned when measuring in all directions.
Thus an antenna pattern which is increasing radiation in the room corners and borders for compensation of free space loss is needed.
In this contribution a specification of classical room sizes in retirement homes are given.
A method for shaping the antenna gain in the E-plane by an one-dimensional series-fed traveling wave patch array and
in the H-plane by an antenna feeding network for improvement of people detection in the room borders and corners is presented for a 24 GHz digital beamforming (DBF) radar system. The feeding network is a parallel-fed power divider for microstrip patch antennas at 24 GHz.
Both approaches are explained in theory.
The design parameters and the layout of the antennas are given.
The simulation of the antenna arrays are executed with CST MWS.
Simulations and measurements of the proposed antennas are compared to each other.
Both antennas are used for the transmit and the receive channel either.
The sensor topology of the radar system is explained.
Furthermore the measurement results of the protoype are presented and discussed.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e112">Because of the rising amount of elderly people in retirement homes and the non-continuous observation by caretakers, the early recognition of emergencies should be improved further.
To ensure a normal everyday life for these people a conventional vital sign monitor can not be used.
The goal is to achieve a non-invasive alternative with a planar microstrip patch antenna based radar system which can monitor people's vital signs while they move freely around in their home.
There have been many activities in microwave-based vital sign monitoring in the last decade as active radar MMICs become less expensive.
Radar is a breaking technology for vital sign monitoring because microwaves are invisible and can penetrate through dry clothing and walls.
Many activities are based on standard radar systems (classical CW or FMCW systems) with conventional antenna designs and by optimizing the signal processing <xref ref-type="bibr" rid="bib1.bibx12" id="paren.1"/>. Signal processing in the time domain based on matched filters, auto-correlation or cross-correlation with sample functions is preferred.
A very good overview about vital sign radar activities for different applications like elderly people monitoring, children monitoring (against sudden infant death syndrome) or driver's health monitoring is summarized in <xref ref-type="bibr" rid="bib1.bibx13" id="text.2"/>.</p>
      <p id="d1e121">In two former conference contributions the authors have shown in detail the concept of the antenna design for monitoring elderly people in retirement homes <xref ref-type="bibr" rid="bib1.bibx8 bib1.bibx9" id="paren.3"/>.</p>
      <?pagebreak page98?><p id="d1e127"><?xmltex \hack{\newpage}?>The authors tried to optimize the technological prerequisite in order to improve the subsequent signal processing.
Thus a digital beamforming system with 2 TX and 4 RX-channels will be applied. The technological setup has already been outlined in <xref ref-type="bibr" rid="bib1.bibx10" id="text.4"/>.
In this work the antenna design and the technological setup are combined to a prototype system. Preliminary measurements are done and presented in this paper.</p>
      <p id="d1e134">The system is designed for installation on the ceiling of a standard room in a retirement home, the location is in the middle of the room.
This average size is determined for a conventional room in a retirement home by 3 m in height, 4 m in length and 6 m in width as outlined in
Fig. <xref ref-type="fig" rid="Ch1.F1"/>.
Due to higher distance from the radar system to the corner of the room, than right to the floor below, a standard patch array is unsuitable.
In order to illuminate the rooms perfectly dedicated antenna arrays with a heart-shaped antenna pattern in the E- and the H-plane are developed.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F1"><?xmltex \currentcnt{1}?><label>Figure 1</label><caption><p id="d1e142">Schematic of an exemplarly room in a retirement home.</p></caption>
        <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f01.png"/>

      </fig>

      <p id="d1e151">A microstrip patch antenna line array (LA) is used for compensation by increasing the radiation power in the E-plane direction.
In Sect. 2 the antenna specification is described and in Sect. 3 a solution for pattern design in the E-plane due to a line array (LA) is given.
The design of the proposed antenna and simulation with CST MICROWAVE STUDIO <xref ref-type="bibr" rid="bib1.bibx1" id="paren.5"/> in the K-band at a frequency of 24 GHz are shown. The comparison of measurement and simulation is given.</p>
      <p id="d1e157">The radiation compensation needs to be solved in the H-plane, too.
A parallel feeding network (PFN) for the individual line arrays is designed in order to compensate the gain in the H-plane.
In Sect. 4 the transmission characteristics and the feeding network design will be described and the microstrip patch antennas are shown.</p>
      <p id="d1e160">In Sect. 5 the sensor set-up and the layout is described.
Measurement results of the complete prototype system will be shown. The influence of the antenna farfield is discussed. Section 6 concludes this paper.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Antenna specification</title>
      <p id="d1e171">The average room size in retirement homes is supposed to be 3 m in height, 6 m in length and 4 m in width as outlined in Fig. <xref ref-type="fig" rid="Ch1.F1"/>.
These dimensions are taken from an exemplary room in a retirement homes of the cooperative project partner.
Of course, these dimensions will vary between different retirement homes slightly, the general concept of radiation enforcement in non-broadside direction is essential for “ceiling-to-bottom-looking” radar systems. Objects in the room which are not shadowing people to be monitored are later on cancelled out by the signal processing due to their static behaviour.</p>
      <p id="d1e176">In order to monitor the complete floor area a triangle with a base of 4 m and the height of 3 m is assumed for the radiation pattern. As the sensor will be installed in the middle of the roof the triangle is symmetric. Thus a opening angle for the antenna would be <inline-formula><mml:math id="M1" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">33.7</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>. The distance from the sensor to the floor (direction defined as <inline-formula><mml:math id="M2" display="inline"><mml:mrow><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M3" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) is 3 m, from sensor to the floor-wall corner (<inline-formula><mml:math id="M4" display="inline"><mml:mrow><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M5" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mo>±</mml:mo><mml:mn mathvariant="normal">33.7</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) is 3.6 m.
Analyzing the radar equation
          <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M6" display="block"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">t</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>G</mml:mi><mml:mi mathvariant="normal">TX</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:msub><mml:mi>G</mml:mi><mml:mi mathvariant="normal">RX</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:msup><mml:mi mathvariant="italic">λ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>⋅</mml:mo><mml:mi mathvariant="italic">σ</mml:mi></mml:mrow><mml:mrow><mml:mo>(</mml:mo><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="italic">π</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:msup><mml:mo>⋅</mml:mo><mml:msup><mml:mi>R</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></disp-formula>
        shows that for targets with constant radar target cross section <inline-formula><mml:math id="M7" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula> the receive power at a radar with isotropic antenna pattern (<inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:msub><mml:mi>G</mml:mi><mml:mi mathvariant="normal">RX</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>G</mml:mi><mml:mi mathvariant="normal">TX</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>∀</mml:mo><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="italic">φ</mml:mi></mml:mrow></mml:math></inline-formula>) is more than factor <inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> lower when located in the corner instead of to be located directly below the sensor. In addition patch antennas radiate their maximum of power in the broadside direction (<inline-formula><mml:math id="M10" display="inline"><mml:mrow><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) thus the receive power of targets below the sensor is much higher compared to targets in the corner.
As the radiation pattern of the receive antenna is multiplied with the pattern of the transmit antenna it is sufficient to modify only one antenna in order to compensate the power reduction due to angle and distance, at least for one plane, E-plane or H-plane.</p>
      <p id="d1e406">The free-space loss due to higher distance at <inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">33.7</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is 4dB, the power reduction of a standard patch antenna under <inline-formula><mml:math id="M13" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">33.7</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> for the transmit antenna is approx. 3-4dB. Thus the receiving line-array needs to have an approx. 10dB higher gain in <inline-formula><mml:math id="M14" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">33.7</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> compared to broadside direction.
          <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M15" display="block"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mo>,</mml:mo><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">33.7</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mo>,</mml:mo><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mn mathvariant="normal">10</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">dB</mml:mi></mml:mrow></mml:math></disp-formula>
        For this the amplitude and phase of single patches with distance of <inline-formula><mml:math id="M16" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> need to be found which can easily be done with the farfield array toolbox of CST MICROWAVE STUDIO. Here a superposition of three times a standard patch shifted in space and phase and with adjusted amplitudes are calculated.</p><?xmltex \hack{\newpage}?>
</sec>
<?pagebreak page99?><sec id="Ch1.S3">
  <label>3</label><title>Traveling wave line array antenna (LA) for beamforming in the E-plane</title>
      <p id="d1e557">In the actual prototype a radar MMIC is used which has 2 transmit channels and 4 receive channels (only I-signals), the latter are used for a digital beamforming application in the H-plane. Thus the spacing between the antenna is only <inline-formula><mml:math id="M17" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>d</mml:mi><mml:mo>=</mml:mo><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> and only one-dimensional line-arrays are possible. This allows beamshaping in the E-plane which will compensate the radiation pattern of the transmit antenna with parallel feeding network (PFN, in next section) which will be a standard patch array with beamshaping in the H-plane.</p>
      <p id="d1e578">The parameters which fulfill the antenna specification in the section before are given in Table <xref ref-type="table" rid="Ch1.T1"/>, the superposition of radiation pattern corresponding to the table are found in Fig. <xref ref-type="fig" rid="Ch1.F2"/>.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e588">Phase and amplitudes of patch antennas to fulfill the specification.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Antenna <inline-formula><mml:math id="M18" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">amplitude <inline-formula><mml:math id="M19" display="inline"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Phase</oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M20" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula>-Position</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">(<inline-formula><mml:math id="M21" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col4">(mm)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Patch 1</oasis:entry>
         <oasis:entry colname="col2">1</oasis:entry>
         <oasis:entry colname="col3">0</oasis:entry>
         <oasis:entry colname="col4">12.5</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Patch 2</oasis:entry>
         <oasis:entry colname="col2">2</oasis:entry>
         <oasis:entry colname="col3">175</oasis:entry>
         <oasis:entry colname="col4">6.25</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Patch 3</oasis:entry>
         <oasis:entry colname="col2">1</oasis:entry>
         <oasis:entry colname="col3">0</oasis:entry>
         <oasis:entry colname="col4">0.00</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2"><?xmltex \currentcnt{2}?><label>Figure 2</label><caption><p id="d1e718">Artificial antenna pattern of line-array due to superposition.</p></caption>
        <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f02.png"/>

      </fig>

      <p id="d1e727">The complete line array will consist of three microstrip patch resonators which are series-fed with microstrip lines. The last patch would be a single-port standard patch. The patches are optimized in radiation for 24.125 GHz, the center of the 24 GHz ISM band. The substrate is a RO4835 material with a design permittivity <inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ϵ</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3.72</mml:mn></mml:mrow></mml:math></inline-formula>. The microstrip line width for a <inline-formula><mml:math id="M23" display="inline"><mml:mrow><mml:mn mathvariant="normal">50</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula> transmission line is <inline-formula><mml:math id="M24" display="inline"><mml:mrow><mml:msub><mml:mi>w</mml:mi><mml:mi mathvariant="normal">t</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.507</mml:mn></mml:mrow></mml:math></inline-formula> mm.
The first two patches are two-port patches for which the design parameters need to be determined.</p>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Design of Microstrip Patches</title>
      <p id="d1e777">Each single patch is designed for low reflection with <inline-formula><mml:math id="M25" display="inline"><mml:mrow><mml:mi mathvariant="normal">Γ</mml:mi><mml:mo>≈</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow></mml:math></inline-formula> at the feeding port (port 1). In the following the balance between radiated power and transmitted power to port 2 is adjusted.
The last patch (<inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>) with power absorption of 100 % is already finished. The amplitude of the second patch (<inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) is twice the amplitude of the last patch which yield a four times higher power. Thus the second patch needs to accept the power which is radiated by itself and the power which is transmit to the last antenna. The radiated power of antenna <inline-formula><mml:math id="M28" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> is given with
            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M29" display="block"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">in</mml:mi></mml:msub><mml:mo>⋅</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msup><mml:mfenced close="|" open="|"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>k</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:msubsup><mml:mo>∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>k</mml:mi></mml:msubsup><mml:msup><mml:mfenced open="|" close="|"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:math></disp-formula>
          The transmission coefficient <inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is given with
            <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M31" display="block"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:msqrt><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msubsup><mml:mo>∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mrow><mml:mi>k</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msubsup><mml:msup><mml:mfenced open="|" close="|"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:msubsup><mml:mo>∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>k</mml:mi></mml:msubsup><mml:msup><mml:mfenced open="|" close="|"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:msqrt><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>-</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msup><mml:mfenced open="|" close="|"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>k</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:msubsup><mml:mo>∑</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow><mml:mi>k</mml:mi></mml:msubsup><mml:msup><mml:mfenced close="|" open="|"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle></mml:mrow></mml:msqrt></mml:mrow></mml:math></disp-formula>
          Table <xref ref-type="table" rid="Ch1.T2"/> shows the transmission coefficients which should be adapted to the given amplitudes. The phase of the coefficient will be adjusted later by conventional delay lines.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e1007">Radiated power and transmission coefficient S21 of each patch.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Antenna</oasis:entry>
         <oasis:entry colname="col2">rad. power</oasis:entry>
         <oasis:entry colname="col3">S21 (db)</oasis:entry>
         <oasis:entry colname="col4">S21 (lin.)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Patch 3</oasis:entry>
         <oasis:entry colname="col2">0.166</oasis:entry>
         <oasis:entry colname="col3">none</oasis:entry>
         <oasis:entry colname="col4">none</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Patch 2</oasis:entry>
         <oasis:entry colname="col2">0.666</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M32" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">7.99</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">0.447</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Patch 1</oasis:entry>
         <oasis:entry colname="col2">0.166</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M33" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.79</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">0.912</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e1106">The adjustment of the recess length <inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:msub><mml:mi>l</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> at the input port has the most effect on the input reflection. The patch width <inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:msub><mml:mi>w</mml:mi><mml:mi mathvariant="normal">p</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> but also the recess length <inline-formula><mml:math id="M36" display="inline"><mml:mrow><mml:msub><mml:mi>l</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and recess width <inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:msub><mml:mi>w</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> at the output port are influencing the transmission coefficient <inline-formula><mml:math id="M38" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.
Thus the reflection and the transmission can mostly be controlled independently. The input reflection of each patch is lower than 12dB in the complete ISM band. The dimensions and the patch design are given in Fig. <xref ref-type="fig" rid="Ch1.F3"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F3"><?xmltex \currentcnt{3}?><label>Figure 3</label><caption><p id="d1e1170">The dimensions of the first and middle two-port patches.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f03.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4" specific-use="star"><?xmltex \currentcnt{4}?><label>Figure 4</label><caption><p id="d1e1181">Simulation of <inline-formula><mml:math id="M39" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <italic>linear</italic> for first patch (<inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>) above and middle patch (<inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) below.</p></caption>
          <?xmltex \igopts{width=483.69685pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f04.png"/>

        </fig>

      <p id="d1e1228">The first patch (<inline-formula><mml:math id="M42" display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>) reaches a reflection of <inline-formula><mml:math id="M43" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">24</mml:mn></mml:mrow></mml:math></inline-formula> dB and the middle patch (<inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) <inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">19.5</mml:mn></mml:mrow></mml:math></inline-formula> dB at the center frequency of the ISM band (24.125 GHz).
The resulting transmission parameters are shown in Fig. <xref ref-type="fig" rid="Ch1.F4"/> with linear scale for better understanding (all further S-Parameters are given in logarithmic scale).
The first patch achieves a transmission of <inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.89</mml:mn></mml:mrow></mml:math></inline-formula> and the middle patch of <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.46</mml:mn></mml:mrow></mml:math></inline-formula> in the relevant frequency range. Compared with Table <xref ref-type="table" rid="Ch1.T2"/>, these values are close to the specifications.</p>
</sec>
<?pagebreak page100?><sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Feeding design</title>
      <p id="d1e1332">The spacing between the patches is <inline-formula><mml:math id="M48" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> which equals <inline-formula><mml:math id="M49" display="inline"><mml:mn mathvariant="normal">6.25</mml:mn></mml:math></inline-formula> mm.
The length of the patches is around <inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:msub><mml:mi>l</mml:mi><mml:mi mathvariant="normal">p</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3.167</mml:mn></mml:mrow></mml:math></inline-formula> mm up to <inline-formula><mml:math id="M51" display="inline"><mml:mn mathvariant="normal">3.4</mml:mn></mml:math></inline-formula> mm.
Due to the different patch lengths variable spacings appear between the patches.
There is a space of <inline-formula><mml:math id="M52" display="inline"><mml:mn mathvariant="normal">2.838</mml:mn></mml:math></inline-formula> mm between patch 1 to patch 2 and of <inline-formula><mml:math id="M53" display="inline"><mml:mn mathvariant="normal">2.9708</mml:mn></mml:math></inline-formula> mm between patch 2 to patch 3.
This space is used for phase adjustment of the several patches.
The phase difference corresponding to the specification in Table <xref ref-type="table" rid="Ch1.T1"/> is defined from the reference plane of the first patch which is the patch edge at the ending of the recess to the comparable reference planes of the subsequent patches.
The feeding microstrip lines are designed as short as possible in order to reduce the losses.
The design of the feeding lines is shown in Fig. <xref ref-type="fig" rid="Ch1.F3"/>, too.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Antenna simulation</title>
      <p id="d1e1403">In Fig. <xref ref-type="fig" rid="Ch1.F5"/> the completed one-dimensional antenna line array is shown.
The total antenna length is <inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:mi>l</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">15.694</mml:mn></mml:mrow></mml:math></inline-formula> mm and the maximum width is <inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:mi>w</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">6.3389</mml:mn></mml:mrow></mml:math></inline-formula> mm.
In Fig. <xref ref-type="fig" rid="Ch1.F6"/> the antenna reflection coefficent is shown by simulation.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><?xmltex \currentcnt{5}?><label>Figure 5</label><caption><p id="d1e1436">Design of the complete line-array.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f05.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6" specific-use="star"><?xmltex \currentcnt{6}?><label>Figure 6</label><caption><p id="d1e1447">Simulation of <inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> for the complete line-array.</p></caption>
          <?xmltex \igopts{width=455.244094pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f06.png"/>

        </fig>

      <p id="d1e1468">A reflection of less than <inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">15</mml:mn></mml:mrow></mml:math></inline-formula> dB is obtained in the 24 GHz ISM band and the minimal reflection of <inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">24.85</mml:mn></mml:mrow></mml:math></inline-formula> dB is reached at the center frequency of <inline-formula><mml:math id="M59" display="inline"><mml:mn mathvariant="normal">24.125</mml:mn></mml:math></inline-formula> GHz.
For this antenna design a sensitivity analysis has not been done separately, a general analysis of production tolerances in the EUROCIRCUIT manufacturing process has been executed by the authors in <xref ref-type="bibr" rid="bib1.bibx5" id="text.6"/>. It is assumed that the deviations in resonance frequency and amplitude in the presented antenna design will be comparable to those in <xref ref-type="bibr" rid="bib1.bibx5" id="text.7"/>.
The farfield in the E-plane yields a satisfying pattern with a gain difference of 8 dB at 0<inline-formula><mml:math id="M60" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> compared to 33.7<inline-formula><mml:math id="M61" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula> which is shown in Fig. <xref ref-type="fig" rid="Ch1.F7"/>.
Due to the microstrip feeding of the single patches the radiation of the single patches is not symmetric and the radiation pattern is squinted. Thus a symmetric pattern of the line array is not achieved.
The total 3D antenna farfield pattern is shown in Fig. <xref ref-type="fig" rid="Ch1.F8"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F7"><?xmltex \currentcnt{7}?><label>Figure 7</label><caption><p id="d1e1529">Simulation of the farfield in the E-Plane for complete line-array.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f07.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8"><?xmltex \currentcnt{8}?><label>Figure 8</label><caption><p id="d1e1540">3D Farfield simulation of the complete line-array.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f08.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>Measurement</title>
      <p id="d1e1557">The line array antenna was developed for a design permittivity of 3.66 which is given as number in the datasheet of ROGERS at 10 GHz and for a permittivity of 3.72 which could be taken from a measurement graph in the datasheet. Both antennas have been processed at the EUROCIRCUITS process which has been investigated for RF designs in <xref ref-type="bibr" rid="bib1.bibx5 bib1.bibx6" id="text.8"/>.
The photo is shown in Fig. <xref ref-type="fig" rid="Ch1.F9"/> which is later in the manuscript. The antennas are connected to a matched connector described in <xref ref-type="bibr" rid="bib1.bibx2" id="text.9"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9"><?xmltex \currentcnt{9}?><label>Figure 9</label><caption><p id="d1e1570">PCB with both manufactured patch antennas.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f09.jpg"/>

        </fig>

      <p id="d1e1579">The antennas are measured with a Rohde&amp;Schwarz ZNB40 network analyzer and the connectors are deembed with the method explained in <xref ref-type="bibr" rid="bib1.bibx4" id="text.10"/>. The reflection coefficient is shown in Fig. <xref ref-type="fig" rid="Ch1.F10"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10"><?xmltex \currentcnt{10}?><label>Figure 10</label><caption><p id="d1e1590">Reflection coefficient <inline-formula><mml:math id="M62" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of both antenna line-arrays after deembedding.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f10.png"/>

        </fig>

      <p id="d1e1610">The antenna pattern in the E-plane is measured again with the Rohde&amp;Schwarz ZNB40 and a horn antenna ARRA 42-862 with an operation range from 18 up to 26,5 GHz in the anechoic chamber of Trier University of Applied Sciences.</p>
      <p id="d1e1613">The results and the comparison with the farfield simulation is depicted in Fig. <xref ref-type="fig" rid="Ch1.F11"/>.
The S-Parameters of the antenna designed with a relative permittivity of <inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ε</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3.72</mml:mn></mml:mrow></mml:math></inline-formula> are fitting very well for the reflection coefficient. The complete 24 GHz ISM band is covered with a maximum reflection coefficient of <inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub><mml:mo>&lt;</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:math></inline-formula> dB. Also the antenna design for <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ε</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3.66</mml:mn></mml:mrow></mml:math></inline-formula> is below <inline-formula><mml:math id="M66" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub><mml:mo>&lt;</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:math></inline-formula> dB for the complete ISM band, but the fit with the simulation is not good. This shows, that for CST MWS simulation (without the new roughness modell) of patch antennas in the 24 GHz ISM band a permittivity of <inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ε</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3.72</mml:mn></mml:mrow></mml:math></inline-formula> should be used. In addition the fit between the simulated and measured farfield results are sufficient but should be optimized in a further design review. Especially at broadside direction an additional beam is occuring which is assumed to be caused by surface wave edge effects of the PCB. Nevertheless the antenna characteristics meet the antenna specification.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F11"><?xmltex \currentcnt{11}?><label>Figure 11</label><caption><p id="d1e1700">Comparison of simulation and measurement results of the farfield in the E-plane for both antennas.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f11.png"/>

        </fig>

</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Parallel feeding network (PFN) for beamforming in the H-plane</title>
      <p id="d1e1718">The radiation compensation needs to be solved in the H-Plane, too.
A parallel feeding network for the individual line arrays is designed in order to compensate the gain in the H-plane.
In the following the parallel feeding network (PFN) connection to microstrip patch antennas is shown.
The parallel fed patches transmitted power and phase can be determined as similar as for the line arrays.
Deduced from the specified room size a radiation angle of <inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">45</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is required.
In this case the radiation pattern of a single patch antenna which has been simulated before is superposed for three patches adjacent to each other (in H-plane dir.) with a distance of <inline-formula><mml:math id="M69" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d1e1747">The resulting specifications are shown in Table <xref ref-type="table" rid="Ch1.T3"/>. The related farfield radiation in the H-plane is shown in Fig. <xref ref-type="fig" rid="Ch1.F12"/>.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e1757">Phase and amplitudes of patch antennas to fulfill the specification.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Antenna</oasis:entry>
         <oasis:entry colname="col2">amplitude</oasis:entry>
         <oasis:entry colname="col3">Phase (<inline-formula><mml:math id="M70" display="inline"><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:math></inline-formula>)</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Patch 1</oasis:entry>
         <oasis:entry colname="col2">0.4</oasis:entry>
         <oasis:entry colname="col3">0</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Patch 2</oasis:entry>
         <oasis:entry colname="col2">0.8</oasis:entry>
         <oasis:entry colname="col3">165</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Patch 3</oasis:entry>
         <oasis:entry colname="col2">0.4</oasis:entry>
         <oasis:entry colname="col3">0</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <?xmltex \floatpos{t}?><fig id="Ch1.F12"><?xmltex \currentcnt{12}?><label>Figure 12</label><caption><p id="d1e1837">Simulated H-Plane PFN Farfield.</p></caption>
        <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f12.png"/>

      </fig>

      <?pagebreak page101?><p id="d1e1846"><?xmltex \hack{\newpage}?>The required radiation difference between the broadside direction (<inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) and the corner direction (<inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:mi mathvariant="italic">γ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">45</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) is 12 dB
          <disp-formula id="Ch1.E5" content-type="numbered"><label>5</label><mml:math id="M73" display="block"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">45</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mo>,</mml:mo><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mo>,</mml:mo><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mn mathvariant="normal">12</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">dB</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p><?xmltex \hack{\newpage}?>
<?pagebreak page102?><sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Three-step Microstrip Power Divider</title>
      <p id="d1e1970">Based on the specifications in Table <xref ref-type="table" rid="Ch1.T3"/> a three-step power divider needs to be build.
This power divider has to divide the input power in three branches which run parallel in a distance of <inline-formula><mml:math id="M74" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mo>=</mml:mo><mml:mn mathvariant="normal">6.213</mml:mn></mml:mrow></mml:math></inline-formula> mm.
The center branch guides a wave whose power is four times higher than the outer branches and requires a phaseshift of <inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:mn mathvariant="normal">165</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d1e2003">Due to the high power difference in the branches a direct power division can not easily be realised because the required input impedances would have extreme values (e.g. <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mn mathvariant="normal">160</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula> which is higher than the maximum realisable microstrip impedance of <inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:mn mathvariant="normal">80</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula>). Thus the idea is to split the power division in three steps. This idea enables the possibility to realise high power differences with high precision at the output ports. For these two Wilkinson Power Dividers and one combiner are used. To reduce the reflection loss, quarter wavelength transformers are used to match the <inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:mn mathvariant="normal">50</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula> signal line. Both, power divider and transformer, are described in <xref ref-type="bibr" rid="bib1.bibx7" id="text.11"/>.
In total four dividers are needed which are simulated separately to achieve higher accuracy.
By reason of the simulation results of <xref ref-type="bibr" rid="bib1.bibx8" id="text.12"/> a relative design permittivity of <inline-formula><mml:math id="M79" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ϵ</mml:mi><mml:mi mathvariant="normal">r</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3.72</mml:mn></mml:mrow></mml:math></inline-formula> is used.</p>
      <p id="d1e2058">The first used divider needs to seperate the input power in two identic signals with half of the power. Thus, to achieve a power ratio of 1 : 1, both branch impedances have to be two<?pagebreak page103?> times higher than the divider input impedance. A divider input impedance of <inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:mn mathvariant="normal">25</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula> is chosen, so the branch impedances is the standard <inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:mn mathvariant="normal">50</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula> signal line. The microstrip width is approximated by the formulas described in <xref ref-type="bibr" rid="bib1.bibx7" id="text.13"/> and exactly determined in use of CST MICROWAVE STUDIO. In Fig. <xref ref-type="fig" rid="Ch1.F13"/> the first divider layout is shown on the left side. The simulated transmission coefficient in both branches amounts to <inline-formula><mml:math id="M82" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3.6</mml:mn></mml:mrow></mml:math></inline-formula> dB.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F13"><?xmltex \currentcnt{13}?><label>Figure 13</label><caption><p id="d1e2099">First Power Divider with ratio 1 : 1 (left side) and second Power Divider with ratio 2 : 1 (right side).</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f13.png"/>

        </fig>

      <?pagebreak page104?><p id="d1e2108"><?xmltex \hack{\newpage}?>Both branches are guided next in a divider with a power ratio of 2 : 1. So the previous split power is now divided to <inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>. Thus the impedance value in the left branch is three times higher, in the right branch <inline-formula><mml:math id="M85" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> times higher than the divider input impedance. Due to the EUROCIRCUITS manufacturing process, the microstrip width is limited at least at 100 <inline-formula><mml:math id="M86" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>m. The maximum impedance at ROGERS RO4835is <inline-formula><mml:math id="M87" display="inline"><mml:mrow><mml:mn mathvariant="normal">90</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula>. Because of the already determined impedances in the previous power divider, the divider input impedance is set to <inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:mn mathvariant="normal">25</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula>. The branch impedances result in <inline-formula><mml:math id="M89" display="inline"><mml:mrow><mml:mn mathvariant="normal">75</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M90" display="inline"><mml:mrow><mml:mn mathvariant="normal">37.5</mml:mn><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula>.
In Fig. <xref ref-type="fig" rid="Ch1.F13"/> the second divider is shown on the right side.
In the upper left branch a transmission of <inline-formula><mml:math id="M91" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">5.6</mml:mn></mml:mrow></mml:math></inline-formula> dB and in the right of <inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2.16</mml:mn></mml:mrow></mml:math></inline-formula> dB at 24.125 GHz is achieved by simulation, thus a power ratio of 2.2 : 1 results.
By use of a recess slot in the branch the transmission characteristic can be adjusted.</p>
      <p id="d1e2219">Two of the resulting microstrip lines conduct <inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:math></inline-formula> and two further lines conduct <inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> of the input power. Combining the two latter microstrip lines which conduct <inline-formula><mml:math id="M95" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> of the input power will yield a four times higher transmit power than the two outer branches. Because both of these branches guide the same mode, the previous designed 1 : 1 power divider can be reversed as power combiner. Due to symmetric excitation on the two input ports the resistance which is typical for Wilkinson Dividers could be neglected.
Power combining both branches yields a simulated transmission of <inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">0.442</mml:mn></mml:mrow></mml:math></inline-formula> dB.</p><?xmltex \hack{\newpage}?>
</sec>
<?pagebreak page105?><sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Complete Parallel Feeding Network</title>
      <p id="d1e2284">After simulating the dividers in a segmented approach, the dividers and the combiner are merged to a final layout. The resulting Parallel Feeding Network (PFN) has a total length of <inline-formula><mml:math id="M97" display="inline"><mml:mn mathvariant="normal">28.334</mml:mn></mml:math></inline-formula> mm and width of <inline-formula><mml:math id="M98" display="inline"><mml:mn mathvariant="normal">15.57</mml:mn></mml:math></inline-formula> mm and is shown in Fig. <xref ref-type="fig" rid="Ch1.F14"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F14"><?xmltex \currentcnt{14}?><label>Figure 14</label><caption><p id="d1e2305">Structure of Parallel Feeding Network including single patch antennas.</p></caption>
          <?xmltex \igopts{width=199.169291pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f14.png"/>

        </fig>

      <?xmltex \floatpos{p}?><fig id="Ch1.F15" specific-use="star"><?xmltex \currentcnt{15}?><label>Figure 15</label><caption><p id="d1e2316">Input reflection coefficient of Parallel Feeding Network.</p></caption>
          <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f15.png"/>

        </fig>

      <p id="d1e2326">The return loss minimum is located outside of the 24 GHz ISM band at 24.9 GHz at <inline-formula><mml:math id="M99" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">33</mml:mn></mml:mrow></mml:math></inline-formula> dB, however a return loss of <inline-formula><mml:math id="M100" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">24.7</mml:mn></mml:mrow></mml:math></inline-formula> dB at 24.125 GHz is achieved which is given in Fig. <xref ref-type="fig" rid="Ch1.F15"/>.</p>

      <?xmltex \floatpos{p}?><fig id="Ch1.F16" specific-use="star"><?xmltex \currentcnt{16}?><label>Figure 16</label><caption><p id="d1e2353">Parallel Feeding Network transmission <inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <bold>(a)</bold> and <inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">31</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> <bold>(b)</bold>.</p></caption>
          <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f16.png"/>

        </fig>

      <p id="d1e2390">The two outer branches are extended with additionally microstrip lines in order to reach the phaseshift difference of <inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:mn mathvariant="normal">165</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> to the inner branch.
In the outer branches (port 2 and 4 in Fig. <xref ref-type="fig" rid="Ch1.F14"/>) a transmission of <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">8.98</mml:mn></mml:mrow></mml:math></inline-formula> dB and the inner branch (port 3 in Fig. <xref ref-type="fig" rid="Ch1.F14"/>) a transmission of <inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2.92</mml:mn></mml:mrow></mml:math></inline-formula> dB is achieved in the simulation thus a total power difference of 4.017 : 1 is attained as it is shown in Fig. <xref ref-type="fig" rid="Ch1.F16"/> for both ports.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F17" specific-use="star"><?xmltex \currentcnt{17}?><label>Figure 17</label><caption><p id="d1e2434">Return loss <inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of Parallel Fed Array.</p></caption>
          <?xmltex \igopts{width=497.923228pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f17.png"/>

        </fig>

      <p id="d1e2454">By reason of the feeding network radiation, mainly in the E-Plane, which interferes with the radiation pattern of the patch antennas, the feeding network and the patch antennas are separated on top and bottom layer. Since the sensor prototype is built on a 4-layer PCB, the test antennas are designed likewise. To conduct the signal to another layer, the microstrip line vias designed in <xref ref-type="bibr" rid="bib1.bibx11" id="text.14"/> are used. First, a test antenna with the PFN and single patches is simulated which is outlined in Fig. <xref ref-type="fig" rid="Ch1.F14"/>. Thus the radiation pattern in the H-plane and accuracy of the parallel feeding can be evaluated.
The simulated antenna reflection coefficient is depicted in Fig. <xref ref-type="fig" rid="Ch1.F17"/>.</p>
      <p id="d1e2465">In the whole 24 GHz ISM band a reflection lower than <inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:mi mathvariant="normal">|</mml:mi><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub><mml:mi mathvariant="normal">|</mml:mi><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:math></inline-formula> dB is accomplished.
Due to the feeding network there is also radiation on the backside of the PCB which is depicted in Fig. <xref ref-type="fig" rid="Ch1.F18"/>. According to simulation a gain difference of about <inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">20</mml:mn></mml:mrow></mml:math></inline-formula> dB results.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F18"><?xmltex \currentcnt{18}?><label>Figure 18</label><caption><p id="d1e2503">Farfield Simulation of Parallel Fed Array, H-Plane.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f18.png"/>

        </fig>

</sec>
<sec id="Ch1.S4.SS3">
  <label>4.3</label><title>Measurements</title>
      <p id="d1e2520">First, the feeding network is manufactured (Fig. <xref ref-type="fig" rid="Ch1.F19"/>) on a Rogers RO4835 (10 mil) substrate and measured with a Rohde&amp;Schwarz ZNB40 network analyzer. A reflection minimum of <inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:mi mathvariant="normal">|</mml:mi><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub><mml:mi mathvariant="normal">|</mml:mi><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">33.25</mml:mn></mml:mrow></mml:math></inline-formula> dB at the center frequency of 24.125 GHz is obtained in Fig. <xref ref-type="fig" rid="Ch1.F20"/>.
The transmission coefficients of all three branches result in a transmission difference of factor 3.86, with a transmission of <inline-formula><mml:math id="M110" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6.35</mml:mn></mml:mrow></mml:math></inline-formula> dB in the middle branch and a transmission of <inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">12.2</mml:mn></mml:mrow></mml:math></inline-formula> dB at the center frequency.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F19"><?xmltex \currentcnt{19}?><label>Figure 19</label><caption><p id="d1e2570">Picture of manufactured parallel feeding network (PFN).</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f19.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F20"><?xmltex \currentcnt{20}?><label>Figure 20</label><caption><p id="d1e2581">Return loss <inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of Parallel Feeding Network Test Structure.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f20.png"/>

        </fig>

      <p id="d1e2602">The measured radiation pattern (realized gain) of the PFN including patch antennas on a second PCB is plotted linearly and compared to the simulation in Fig. <xref ref-type="fig" rid="Ch1.F21"/>. The gain difference of <inline-formula><mml:math id="M113" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">45</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> is <inline-formula><mml:math id="M115" display="inline"><mml:mn mathvariant="normal">11</mml:mn></mml:math></inline-formula> dB which matches the specification.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F21"><?xmltex \currentcnt{21}?><label>Figure 21</label><caption><p id="d1e2648">Simulation and Measurement of the PFA Farfield in H-plane.</p></caption>
          <?xmltex \igopts{width=184.942913pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f21.png"/>

        </fig>

</sec>
</sec>
<sec id="Ch1.S5">
  <label>5</label><title>Sensor system and prototype</title>
      <p id="d1e2667">In previous sections the authors presented dedicated microstrip patch arrays.
The first antenna is an one-dimensional series-fed traveling wave antenna with a heart-shaped antenna pattern in the E-plane, while the second antenna is parallel-fed and has heart-shaped pattern in the H-plane.</p><?xmltex \hack{\newpage}?>
<?pagebreak page107?><sec id="Ch1.S5.SS1">
  <label>5.1</label><title>Sensor Setup</title>
      <p id="d1e2678">In terms of cost and time reduction in the development, the baseband electronics, signal and voltage supply connectors are taken over from a laboratory radar already implemented in our institution <xref ref-type="bibr" rid="bib1.bibx3" id="paren.15"/>. Thus the PCB outline and the connector placement for the RF front-end is equal to the laboratory radar.
The transmitting part is implemented with an ADF4159 waveform-generator and an ADF5901 VCO and LO which is used for signal generation. As reference clock a 100 MHz oscillator is utilised. The receiving part is set-up with an ADF5904 four channel receiver.
The differential signals, which are received and down-converted, are connected to an AD8422 instrumentation amplifier with single ended outputs. Both kinds of signals are provided for signal processing, the differential signals without gain and the single ended signals with a gain of 200.
For further information about applications of the on-board ICs, the datasheets are highly recommended.
The circuit board manufacturing process for RF PCBs by EUROCIRCUITS has been investigated in <xref ref-type="bibr" rid="bib1.bibx5 bib1.bibx6" id="text.16"/>.</p>
</sec>
<sec id="Ch1.S5.SS2">
  <label>5.2</label><title>RF-Frontend Layout</title>
      <p id="d1e2695">Unlike the electronic components, the transmitting and receiving antennas are located on the PCB downside.
The two transmitting and the four receiving antennas are placed with a spacing of half wavelength of <inline-formula><mml:math id="M116" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">TX</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>d</mml:mi><mml:mi mathvariant="normal">RX</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">6.213</mml:mn></mml:mrow></mml:math></inline-formula> mm to the adjacent antenna.
In consideration of the high space usage of the feeding network, the parallel fed patch array of Sect. 4 is used as transmit antennas.
The one-dimensional series-fed<?pagebreak page108?> microstrip patch arrays of Sect. 3 are used as receive antennas.
To reduce the coupling between transmit and receive antennas on board, the spacing between the two different arrays is determined to <inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mtext>RX/TX</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">11</mml:mn></mml:mrow></mml:math></inline-formula> mm. The schematical layout and an overview about the spacings is given in Figs. <xref ref-type="fig" rid="Ch1.F22"/> and <xref ref-type="fig" rid="Ch1.F23"/>.
Due to the <inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:mi mathvariant="italic">λ</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> spacing of the receive antennas a distinct angle determination is achieved in the H-plane by digital beamforming (DBF) processing.
By switching the power between the two transmit antennas a 2.5D MIMO radar imaging is applied. The angle-of-arrival (AoA) in the E-plane could be measured. Figure <xref ref-type="fig" rid="Ch1.F24"/> shows the front and the back side of the protoype PCB for testing and evaluation.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F22"><?xmltex \currentcnt{22}?><label>Figure 22</label><caption><p id="d1e2756">Block Diagram of the Radar System.</p></caption>
          <?xmltex \igopts{width=170.716535pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f22.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F23" specific-use="star"><?xmltex \currentcnt{23}?><label>Figure 23</label><caption><p id="d1e2767">Block Diagram of the antenna frontend.</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f23.png"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F24"><?xmltex \currentcnt{24}?><label>Figure 24</label><caption><p id="d1e2779">Prototype PCB of the RF front end.</p></caption>
          <?xmltex \igopts{width=184.942913pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f24.jpg"/>

        </fig>

</sec>
<sec id="Ch1.S5.SS3">
  <label>5.3</label><title>Data Acquisition</title>
      <p id="d1e2797">The measurement set-up of <xref ref-type="bibr" rid="bib1.bibx3" id="text.17"/> will be reused as the connector placing is equal.</p>
      <p id="d1e2803">In this set-up National Instrument devices are used:
<list list-type="bullet"><list-item>
      <p id="d1e2808">The docking station cDAQ9174</p></list-item><list-item>
      <p id="d1e2812">The NI9402, a digital input/output module which is used to generate the ramp trigger signal</p></list-item><list-item>
      <p id="d1e2816">The NI9220, an analog input module to provide the data for further signal processing</p></list-item></list>
The measurement is done in the 24 GHz ISM Band. The radar operates works in FMCW mode and is triggered for a ramp repetition frequency of 390 ramps per second. The sampling rate of the NI9220 is 100 000 samples per second which results in 256 samples per ramp.</p>
</sec>
<sec id="Ch1.S5.SS4">
  <label>5.4</label><title>Data Processing</title>
      <p id="d1e2828">The measurement is done in a low reflection absorber chamber in the basement of our institution at the Trier, University of Applied Sciences. The remaining effects can mostly be removed due to a calibration measurement. The goal of the measurement is to detect a corner reflector with a radar cross section of 40 m<inline-formula><mml:math id="M119" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:math></inline-formula>, in a distance of 2 m in five different angles to ensure a wide angle surveillance of the system. These are the directions in which the main radiation of the developed antennas is optimized, additionally the broadside direction as comparison measurement is done. To evaluate all five angles, the corner reflector is located in front of the radar system and the whole radar system has to be turned by a mechanical rotation system in the relevant directions as shown in Fig. <xref ref-type="fig" rid="Ch1.F25"/>.
First the calibration measurements are done in all five directions without corner reflector. Then the empty space can be removed in the measurement afterwards. As example the processed signal of one receive antenna is shown in Fig. <xref ref-type="fig" rid="Ch1.F26"/> with and without the corner reflector.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F25"><?xmltex \currentcnt{25}?><label>Figure 25</label><caption><p id="d1e2846">Measurement set-up for target detection in 2 m distance.</p></caption>
          <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f25.jpg"/>

        </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F26"><?xmltex \currentcnt{26}?><label>Figure 26</label><caption><p id="d1e2857">Comparison of Measurement with and without a target.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f26.png"/>

        </fig>

      <p id="d1e2867">In a distance of 0.5 m a virtual target is detected in both measurements. However no target is placed in that distance, as it could be seen in the measurement setup in Fig. <xref ref-type="fig" rid="Ch1.F25"/>.
On the one hand the corresponding “ghost target” occurs probably due to cross talk of baseband electronics which should be<?pagebreak page109?> fixed in a layout review. On the other hand electronic offset and linear variation during the frequency ramp are enforcing this problem. The latter could by canceled by subtracting the linear regression. For the measurement this specific error is not an obstacle since it can be suppressed by taking into account the calibration which is a difference of both signals.</p>
      <p id="d1e2872">In both measurements the noise ratio of other interferences is reduced due to the absorber chamber, therefore the only difference could be found in a distance of 2 m which is the target's location shown in Fig. <xref ref-type="fig" rid="Ch1.F27"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F27"><?xmltex \currentcnt{27}?><label>Figure 27</label><caption><p id="d1e2879">Range data difference of channel 1 with and without a target in broadside direction.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f27.png"/>

        </fig>

      <?pagebreak page110?><p id="d1e2888">The result is satisfying, since most of the noise and side effects of the measurement are removed and the target in a distance of 2 m is seen.
In Table <xref ref-type="table" rid="Ch1.T4"/> all measured angles and resulting amplitudes of <italic>channel 1</italic> of the radar system are shown.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T4"><?xmltex \currentcnt{4}?><label>Table 4</label><caption><p id="d1e2899">Measured Angles and corresponding Amplitudes.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M120" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mi mathvariant="italic">φ</mml:mi><mml:mo>]</mml:mo><mml:mo>=</mml:mo><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:mo>[</mml:mo><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>]</mml:mo><mml:mo>=</mml:mo><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">Measured</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3">Amplitude</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">0</oasis:entry>
         <oasis:entry colname="col2">0</oasis:entry>
         <oasis:entry colname="col3">0.842</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">0</oasis:entry>
         <oasis:entry colname="col2">45</oasis:entry>
         <oasis:entry colname="col3">1.166</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">0</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M122" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">45</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">0.964</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">90</oasis:entry>
         <oasis:entry colname="col2">45</oasis:entry>
         <oasis:entry colname="col3">2.095</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">90</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M123" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">45</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">1.041</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e3050">Furthermore the corresponding range plots of <italic>channel 1</italic> are given in Fig. <xref ref-type="fig" rid="Ch1.F28"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F28"><?xmltex \currentcnt{28}?><label>Figure 28</label><caption><p id="d1e3060">Range data difference of channel 1 with and without a target in multiple directions.</p></caption>
          <?xmltex \igopts{width=227.622047pt}?><graphic xlink:href="https://ars.copernicus.org/articles/18/97/2020/ars-18-97-2020-f28.png"/>

        </fig>

      <p id="d1e3069"><?xmltex \hack{\newpage}?>In broadside direction, the red trace in Fig. <xref ref-type="fig" rid="Ch1.F28"/>, the received power is the lowest compared to each other direction, which is intended, because the system is installed in the middle of the ceiling. Thus the distance to objects directly below the sensor is lowest.</p>
      <p id="d1e3075">The aim for the remaining directions is to receive a signal with a comparable or even higher amplitude. The measurement results in the H-plane are expected to be the same in both directions, due to the symmetry of the parallel fed array. However the unsymmetric H-plane pattern of the line array also interferes with this direction. Thus the direction <inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">45</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (green trace) and <inline-formula><mml:math id="M126" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">45</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (cyan trace) do not match exactly.
The reason of the H-plane mismatch is identified by the asymmetric round feeding lines between the patches.</p>
      <p id="d1e3144">For both measurements in the E-plane (blue trace for <inline-formula><mml:math id="M128" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">90</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M129" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mo>+</mml:mo><mml:mn mathvariant="normal">45</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> and black trace for <inline-formula><mml:math id="M130" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">90</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M131" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn mathvariant="normal">45</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) the received amplitude in “forward direction” (<inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">90</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M133" display="inline"><mml:mrow><mml:mi mathvariant="italic">θ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">45</mml:mn><mml:msup><mml:mi/><mml:mo>∘</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>) is about twice as much as in the opposite direction. This effect mainly results from the E-plane of the line array, shown in the farfields in Fig. <xref ref-type="fig" rid="Ch1.F11"/> where radiation in forward direction is two times higher than in the “backward direction”. Nevertheless the difference of the ampllitudes is only 3 dB which is much lower compared to classical patch arrays.</p><?xmltex \hack{\newpage}?>
</sec>
</sec>
<?pagebreak page111?><sec id="Ch1.S6" sec-type="conclusions">
  <label>6</label><title>Conclusions</title>
      <p id="d1e3260">In this paper two different antennas for ceiling suspension are developed which compensate free space losses in domestic environments and the typical radiation characteristic of standard patches. The comparison between simulation and the measurement of the antennas are promising, a wide view angle and a compensation of free space losses has been accomplished in order to cover a complete size of an average room as shown in Fig. <xref ref-type="fig" rid="Ch1.F1"/>.
A protoype system for vital sign monitoring of elderly people has been developed.
The results in all radar channels are satisfying, since a wide angle for target detection is achieved.</p>
      <p id="d1e3265">For further design reviews the antenna pattern of the line array in broadside direction and the match to the simulation should be optimised.
The gain difference in the E-plane should be compensated and the squinting in the H-plane, maybe by use of symmetric feeding lines between the patches, could be reduced for the line array.</p>
      <p id="d1e3268">The parallel fed array is matching well to the simulation, but the large space requirements of the feeding is an obstacle.
By finding a solution for this size problem the system dimensions could be minimized.</p>
      <p id="d1e3271">In the next step the prototype is evaluated for standard measurement scenarios and a signal processing software will be developed to measure the breathing rate and the heart-beat rate of people located below the sensor.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e3278">No data sets were used in this article.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e3284">SaS was working as Bachelor student at the Laboratory of Radar Technology and Optical Systems, he designed all antenna elements in CST MWS, transferred the layout to Gerber, manufactured the PCBs and measured these. SM supervised the work in the RF technology and DS supervised the work for microwave based vital sign monitoring and signal processing. ARD is the head of the institution, he gave the initial idea of the application, the design specification of the antennas, the radar system topology and the workflow to proceed the measurements.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e3290">The authors declare that they have no conflict of interest.</p>
  </notes><notes notes-type="sistatement"><title>Special issue statement</title>

      <p id="d1e3296">This article is part of the special issue “Kleinheubacher Berichte 2019”. It is a result of the Kleinheubacher Berichte 2019, Miltenberg, Germany, 23–25 September 2019.</p>
  </notes><ack><title>Acknowledgement</title><p id="d1e3302">The authors would like to thank Dieter Hewener from Senioren-Pflegeheim Holunderbusch GmbH in Lorscheid for the kind introduction into retirement homes and the support in the specification of the prototype room size.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e3307">This research has been supported by the German Federal Ministry of Education and Research (BMBF) within the public funding program “FHProfUnt” with the title “VITASENS” (grant no. 13FH303PX6).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e3313">This paper was edited by Lars Ole Fichte and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>CST(2020)</label><?label CST?><mixed-citation>CST Microwave Studio<sup>®</sup>: <uri>http://www.cst.com/products/cstmws</uri>, last access: 9 September 2020.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Diewald et al.(2017)</label><?label diewald1?><mixed-citation>
Diewald, A. R., Müller, S., and Olk, A.:
PCB-Side Matching Networks for coaxial connectors,
AMTA 2017 Proceedings, Antenna Measurement Techniques Association Symposium (AMTA),  15–20 October 2017, Atlanta, GA, USA, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>Dirksmeyer et al.(2018)</label><?label muller_master?><mixed-citation>Dirksmeyer, L., Diewald, A. R., Müller, S.:
Eight Channel Digital beamforming Radar for Academic Lab Courses and Research,
19th International Radar Symposium, 20–22 June 2018, Bonn, Germany, 2018.
 </mixed-citation></ref><?xmltex \hack{\newpage}?>
      <ref id="bib1.bibx4"><?xmltex \def\ref@label{M\"{u}ller and Diewald(2015)}?><label>Müller and Diewald(2015)</label><?label muller?><mixed-citation>
Müller, S. and Diewald, A. R.:
Methods of Connector S-Parameter Extraction Depending on Broadband Measurements of Symmetrical Structures,
The Loughborough Antennas and Propagation Conference (LAPC) 2015, 11 November 2015, Loughborough, UK, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx5"><?xmltex \def\ref@label{M\"{u}ller et al.(2016a)}?><label>Müller et al.(2016a)</label><?label EUROCIRCUITS1?><mixed-citation>
Müller, S., Thull, R., Huber, M., and Diewald, A. R.:
Microstrip patch antennas on EUROCIRCUITS process,
2016 Loughborough Antennas &amp; Propagation Conference (LAPC), 14–15 November 2016, Loughborough, UK, 2016a.</mixed-citation></ref>
      <ref id="bib1.bibx6"><?xmltex \def\ref@label{M\"{u}ller et al.(2016b)}?><label>Müller et al.(2016b)</label><?label EUROCIRCUITS2?><mixed-citation>
Müller, S., Thull, R., Huber, M., and Diewald, A. R.:
Analysis on microstrip transmission line surface coatings,
2016 Loughborough Antennas &amp; Propagation Conference (LAPC), , 14–15 November 2016, Loughborough, UK, 2016b.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Pozar(2011)</label><?label David?><mixed-citation>
Pozar, D. M.: Microwave Engineering, 4th edn., 10/12, John Wiley &amp; Sons, Inc., Hoboken, USA, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx8"><?xmltex \def\ref@label{Sch\"{a}fer et al.(2018a)}?><label>Schäfer et al.(2018a)</label><?label Paper-LA?><mixed-citation>
Schäfer, S., Schmiech, D., Müller, S., and Diewald, A. R.:
One-dimensional Patch Array for Microwave-based Vital Sign Monitoring of Elderly People,
IRS 2018, International Radar Symposium 2018, 20–22 June 2018, Bonn, Germany, 2018a.</mixed-citation></ref>
      <ref id="bib1.bibx9"><?xmltex \def\ref@label{Sch\"{a}fer et al.(2018b)}?><label>Schäfer et al.(2018b)</label><?label Paper-PFA?><mixed-citation>
Schäfer, S., Schmiech, D., Müller, S., and Diewald, A. R.:
Parallel Fed Patch Array for Microwave-based Vital Sign Monitoring of Elderly People, EuMW 2018, European Microwave Week, 23–27 September 2018, Madrid, Spain, 2018b.</mixed-citation></ref>
      <ref id="bib1.bibx10"><?xmltex \def\ref@label{Sch\"{a}fer et al.(2019)}?><label>Schäfer et al.(2019)</label><?label Paper-Sensor?><mixed-citation>
Schäfer, S., Müller, S., Schmiech, D., and Diewald, A. R.:
Sensor Development for Vital Sign Monitoring of Elderly People,
2019 International Conference on Electromagnetics in Advanced Applications (ICEAA), 9–13 September 2019 , Granada, Spain, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Schmiech et al.(2018)</label><?label Via?><mixed-citation>
Schmiech, D., Müller, S., and Diewald, A. R.:
4-Channel I/Q-Radar system or vital sign monitoring in a baby incubator,
GeMiC 2018, German Microwave Conference, 20–22 June 2018, Freiburg, Germany, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>Will et al.(2015)</label><?label will2?><mixed-citation>
Will, C., Shi, K., Lurz, F., Weigel, R., and Koelpin, A.:
Intelligent signal processing routine for instantaneous heart rate detection using a Six-Port microwave interferometer,
2015 International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS), 9–12 November 2015, Nusa Dua, Indonesia, 483–487, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Will et al.(2017)</label><?label will1?><mixed-citation>
Will, C., Shi, K., Schellenberger, S., Steigleder, T., Michler, F., Weigel, R., Ostgathe, C., and Koelpin, A.:
Local Pulse Wave Detection using Continuous Wave Radar Systems,
IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, 1, 81–89, 2017.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Radar system with dedicated planar traveling wave antennas for elderly people monitoring</article-title-html>
<abstract-html><p>Radar systems for contactless vital sign monitoring are well known and an actual object of research.
These radar-based sensors could be used for monitoring of elderly people in their homes but also for detecting the activity of prisoners and to control electrical devices (light, audio, etc.) in smart living environments.
Mostly these sensors are foreseen to be mounted on the ceiling in the middle of a room.
In retirement homes the rooms are mostly rectangular and of standardized size.
Furniture like beds and seating are found at the borders or the corners of the room.
As the propagation path from the center of the room ceiling to the borders and corners of a room is 1.4 and 1.7 time longer the power reflected by people located there is 6 or even 10&thinsp;dB lower than if located in the center of the room.
Furthermore classical antennas in microstrip technology are strengthening radiation in broadside direction.
Radar systems with only one single planar antenna must be mounted horizontally aligned when measuring in all directions.
Thus an antenna pattern which is increasing radiation in the room corners and borders for compensation of free space loss is needed.
In this contribution a specification of classical room sizes in retirement homes are given.
A method for shaping the antenna gain in the E-plane by an one-dimensional series-fed traveling wave patch array and
in the H-plane by an antenna feeding network for improvement of people detection in the room borders and corners is presented for a 24&thinsp;GHz digital beamforming (DBF) radar system. The feeding network is a parallel-fed power divider for microstrip patch antennas at 24&thinsp;GHz.
Both approaches are explained in theory.
The design parameters and the layout of the antennas are given.
The simulation of the antenna arrays are executed with CST MWS.
Simulations and measurements of the proposed antennas are compared to each other.
Both antennas are used for the transmit and the receive channel either.
The sensor topology of the radar system is explained.
Furthermore the measurement results of the protoype are presented and discussed.</p></abstract-html>
<ref-html id="bib1.bib1"><label>CST(2020)</label><mixed-citation>
CST Microwave Studio<span style="position:relative; bottom:0.5em; " class="text">®</span>: <a href="http://www.cst.com/products/cstmws" target="_blank"/>, last access: 9 September 2020.
</mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Diewald et al.(2017)</label><mixed-citation>
Diewald, A. R., Müller, S., and Olk, A.:
PCB-Side Matching Networks for coaxial connectors,
AMTA 2017 Proceedings, Antenna Measurement Techniques Association Symposium (AMTA),  15–20 October 2017, Atlanta, GA, USA, 2017.
</mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Dirksmeyer et al.(2018)</label><mixed-citation>
Dirksmeyer, L., Diewald, A. R., Müller, S.:
Eight Channel Digital beamforming Radar for Academic Lab Courses and Research,
19th International Radar Symposium, 20–22 June 2018, Bonn, Germany, 2018.

</mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Müller and Diewald(2015)</label><mixed-citation>
Müller, S. and Diewald, A. R.:
Methods of Connector S-Parameter Extraction Depending on Broadband Measurements of Symmetrical Structures,
The Loughborough Antennas and Propagation Conference (LAPC) 2015, 11 November 2015, Loughborough, UK, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Müller et al.(2016a)</label><mixed-citation>
Müller, S., Thull, R., Huber, M., and Diewald, A. R.:
Microstrip patch antennas on EUROCIRCUITS process,
2016 Loughborough Antennas &amp; Propagation Conference (LAPC), 14–15 November 2016, Loughborough, UK, 2016a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Müller et al.(2016b)</label><mixed-citation>
Müller, S., Thull, R., Huber, M., and Diewald, A. R.:
Analysis on microstrip transmission line surface coatings,
2016 Loughborough Antennas &amp; Propagation Conference (LAPC), , 14–15 November 2016, Loughborough, UK, 2016b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Pozar(2011)</label><mixed-citation>
Pozar, D. M.: Microwave Engineering, 4th edn., 10/12, John Wiley &amp; Sons, Inc., Hoboken, USA, 2011.
</mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Schäfer et al.(2018a)</label><mixed-citation>
Schäfer, S., Schmiech, D., Müller, S., and Diewald, A. R.:
One-dimensional Patch Array for Microwave-based Vital Sign Monitoring of Elderly People,
IRS 2018, International Radar Symposium 2018, 20–22 June 2018, Bonn, Germany, 2018a.
</mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Schäfer et al.(2018b)</label><mixed-citation>
Schäfer, S., Schmiech, D., Müller, S., and Diewald, A. R.:
Parallel Fed Patch Array for Microwave-based Vital Sign Monitoring of Elderly People, EuMW 2018, European Microwave Week, 23–27 September 2018, Madrid, Spain, 2018b.
</mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Schäfer et al.(2019)</label><mixed-citation>
Schäfer, S., Müller, S., Schmiech, D., and Diewald, A. R.:
Sensor Development for Vital Sign Monitoring of Elderly People,
2019 International Conference on Electromagnetics in Advanced Applications (ICEAA), 9–13 September 2019 , Granada, Spain, 2019.
</mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Schmiech et al.(2018)</label><mixed-citation>
Schmiech, D., Müller, S., and Diewald, A. R.:
4-Channel I/Q-Radar system or vital sign monitoring in a baby incubator,
GeMiC 2018, German Microwave Conference, 20–22 June 2018, Freiburg, Germany, 2018.
</mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Will et al.(2015)</label><mixed-citation>
Will, C., Shi, K., Lurz, F., Weigel, R., and Koelpin, A.:
Intelligent signal processing routine for instantaneous heart rate detection using a Six-Port microwave interferometer,
2015 International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS), 9–12 November 2015, Nusa Dua, Indonesia, 483–487, 2015.
</mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Will et al.(2017)</label><mixed-citation>
Will, C., Shi, K., Schellenberger, S., Steigleder, T., Michler, F., Weigel, R., Ostgathe, C., and Koelpin, A.:
Local Pulse Wave Detection using Continuous Wave Radar Systems,
IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, 1, 81–89, 2017.
</mixed-citation></ref-html>--></article>
