<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">ARS</journal-id><journal-title-group>
    <journal-title>Advances in Radio Science</journal-title>
    <abbrev-journal-title abbrev-type="publisher">ARS</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Adv. Radio Sci.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">1684-9973</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/ars-20-1-2023</article-id><title-group><article-title>Comparison of <inline-formula><mml:math id="M1" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-Parameter Measurement Methods for Adapters</article-title><alt-title>Comparison of <inline-formula><mml:math id="M2" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-Parameter Measurement Methods</alt-title>
      </title-group><?xmltex \runningtitle{Comparison of $S$-Parameter Measurement Methods}?><?xmltex \runningauthor{K. Kuhlmann et al.}?>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <name><surname>Kuhlmann</surname><given-names>Karsten</given-names></name>
          <email>karsten.kuhlmann@ptb.de</email>
        <ext-link>https://orcid.org/0000-0002-4022-7061</ext-link></contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Gellersen</surname><given-names>Frauke</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no">
          <name><surname>Tschauder</surname><given-names>Meike</given-names></name>
          
        </contrib>
        <aff id="aff1"><institution>High Frequency and Electromagnetic Fields, Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, <?xmltex \hack{\break}?>38116 Braunschweig, Germany</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Karsten Kuhlmann (karsten.kuhlmann@ptb.de)</corresp></author-notes><pub-date><day>21</day><month>March</month><year>2023</year></pub-date>
      
      <volume>20</volume>
      <fpage>1</fpage><lpage>8</lpage>
      <history>
        <date date-type="received"><day>17</day><month>February</month><year>2022</year></date>
           <date date-type="accepted"><day>6</day><month>February</month><year>2023</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2023 Karsten Kuhlmann et al.</copyright-statement>
        <copyright-year>2023</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023.html">This article is available from https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023.html</self-uri><self-uri xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023.pdf">The full text article is available as a PDF file from https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d1e104">In this work two methods for the characterization of adapters meaning reciprocal two-ports with different connector styles on both ports are analyzed and compared in detail. The focus is on the comparison of these approaches in terms of required effort and obtained measurement uncertainty. The first method is based on two one-port calibrations and it is compared to a two-port approach. Both methods are carried out in simulation as well as in measurement under very comparable conditions using a 2.4 to 3.5<inline-formula><mml:math id="M3" display="inline"><mml:mspace width="0.125em" linebreak="nobreak"/></mml:math></inline-formula>mm adapter in the frequency range up to 33<inline-formula><mml:math id="M4" display="inline"><mml:mspace linebreak="nobreak" width="0.125em"/></mml:math></inline-formula>GHz as an example. The obtained measurement uncertainties of the results are presented and analyzed, the required measurement time in terms of the necessary number of separate connections is compared, and the influence of cable movements is discussed.</p>
  </abstract>
    </article-meta>
  </front>
<body>
      

      <?xmltex \floatpos{t}?><fig id="Ch1.F1" specific-use="star"><?xmltex \currentcnt{1}?><?xmltex \def\figurename{Figure}?><label>Figure 1</label><caption><p id="d1e123">Photograph of an adapter measurement.</p></caption>
      <?xmltex \igopts{width=398.338583pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f01.jpg"/>

    </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F2" specific-use="star"><?xmltex \currentcnt{2}?><?xmltex \def\figurename{Figure}?><label>Figure 2</label><caption><p id="d1e134">The 3-term error model used for one-port calibrations (<xref ref-type="bibr" rid="bib1.bibx3" id="altparen.1"/>).</p></caption>
      <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f02.png"/>

    </fig>

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e153">In measurement applications many DUTs (Devices Under Test) with two ports have different interfaces at their two ports and are commonly referred to as adapters. The interface for example can be a coaxial connector, a rectangular waveguide flange, a coplanar waveguide probe tip, or something else.</p>
      <p id="d1e156">Exemplarily, Fig. <xref ref-type="fig" rid="Ch1.F1"/> shows a measurement setup with two adapters (coaxial to rectangular waveguide) being measured in series (sometimes referred to as “back-to-back”). Precise measurements of such components and therefore calibration algorithms for VNAs (Vector Network Analyzers) are needed. In this work two suitable calibration algorithms for the measurement of such adapters are investigated and compared.</p>
      <p id="d1e161">There are some other methods available and described in literature, which are suitable to characterize adapters. A very good overview can be found in <xref ref-type="bibr" rid="bib1.bibx7" id="text.2"/>. However, the two methods evaluated in detail in this work are the most promising to yield a low MU (measurement uncertainty) and are applicable to many types of adapters.</p>
      <p id="d1e167">The first one is a VNA measurement method using only one-port calibration standards and one-port measurements. Here the devices Open, Short, and Match (OSM) are utilized, but other combinations (e.g. three offset shorts) are also possible as calibration standards. The VNA error model for this method is shown in Fig. <xref ref-type="fig" rid="Ch1.F2"/>. It will be compared to a two-port calibration method using an Unknown Thru connection in addition to the OSM standards. This method is often referred to as UOSM (Unknown Thru, Open, Short, Match) or SOLR (Short, Open, Load, Reciprocal) (<xref ref-type="bibr" rid="bib1.bibx2 bib1.bibx8" id="altparen.3"/>), and the error model is shown in Fig. <xref ref-type="fig" rid="Ch1.F3"/>.</p>
      <p id="d1e178">The MU for both methods is evaluated using <xref ref-type="bibr" rid="bib1.bibx10" id="text.4"/>; <xref ref-type="bibr" rid="bib1.bibx5" id="text.5"/>; and <xref ref-type="bibr" rid="bib1.bibx11" id="text.6"/> and the obtained MU and the required effort (e.g. measurement steps and connections), which is related to the measurement time, are compared.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Description of the Calibration Methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>OSM Method</title>
      <p id="d1e206">The OSM method is a one-port measurement method. It includes two one-port VNA calibrations with at least three calibration standards, respectively. The first calibration is performed at the measurement port (reference plane) of the VNA. For the second calibration the first port of the adapter is connected to the VNA and again three known standards are measured, this time connected to the second port of the adapter. Both VNA calibrations yield an error network with three error terms, as depicted in Fig. <xref ref-type="fig" rid="Ch1.F2"/>.</p>

      <?xmltex \floatpos{t}?><?pagebreak page3?><fig id="Ch1.F3" specific-use="star"><?xmltex \currentcnt{3}?><?xmltex \def\figurename{Figure}?><label>Figure 3</label><caption><p id="d1e213">The 7-term error model (<xref ref-type="bibr" rid="bib1.bibx3" id="altparen.7"/>).</p></caption>
          <?xmltex \igopts{width=455.244094pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f03.png"/>

        </fig>

      <?pagebreak page2?><p id="d1e225">The second error network contains the DUT (adapter), while the first one does not. With the assumption of reciprocity (<inline-formula><mml:math id="M5" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">12</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) for the DUT, the first error network is de-cascaded on the left side of the second error network and the <inline-formula><mml:math id="M6" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters (scattering parameters) of the DUT are obtained. To measure several DUTs with this method, the second calibration must be performed several times.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>UOSM Method</title>
      <p id="d1e261">The UOSM method is a full two-port VNA calibration using the 7-term error model (<xref ref-type="bibr" rid="bib1.bibx2" id="altparen.8"/>), and the measurement of the so-called switch terms (<xref ref-type="bibr" rid="bib1.bibx4" id="altparen.9"/>) is required. The obtained error terms are depicted in Fig. <xref ref-type="fig" rid="Ch1.F3"/>.</p>
      <p id="d1e272">If the adapter is used during this calibration as the unknown thru standard, the only requirement is, that it must be reciprocal and the insertion loss (attenuation) should not be too high. For adapters with high insertion loss, the dynamic range of the VNA determines the quality of the calibration result. To avoid this, the insertion loss should be small and the transmission signals <inline-formula><mml:math id="M7" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">12</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> well above the VNA noise level.</p>
      <p id="d1e297">With the error terms obtained, no further connections of calibration standards are required, and several DUTs can be measured one after the other. At least, this is true as long as cable movements (one source of MU) are allowed. If more than one two-port DUT is to be measured, and cable movements must be avoided completely, one set of OSM standards has to be measured in between the DUT measurements to recalibrate one VNA port after the movement of one cable.</p><?xmltex \hack{\newpage}?>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Simulations</title>
      <p id="d1e310">In this section the methods OSM and UOSM are compared without the influence of the measurement set-up. Only the MU of the calibration standards is included. As DUT a coaxial adapter for 3.5 and 2.4 mm interfaces is used.</p>
      <p id="d1e313">While experiments (measurements) are often needed and applied to verify theoretical concepts, simulations have the advantage to work on ideal data. Of course this holds only true if the model is good enough to represent the actual physics. Modeling VNAs as well as the determination of the measurement uncertainties is very well understood and described in <xref ref-type="bibr" rid="bib1.bibx12" id="text.10"/>. Typical influences present in nearly all VNA measurement set-ups are:
<list list-type="bullet"><list-item>
      <p id="d1e321">VNA drift,</p></list-item><list-item>
      <p id="d1e325">VNA noise,</p></list-item><list-item>
      <p id="d1e329">VNA linearity,</p></list-item><list-item>
      <p id="d1e333">connection repeatability,</p></list-item><list-item>
      <p id="d1e337">cable movements,</p></list-item><list-item>
      <p id="d1e341">calibration standards.</p></list-item></list>
These non ideal circumstances will always change, to a small or not so small degree, the nominal result of any experiment, but they can be avoided completely in a simulation. Therefore, except for the MUs of the calibration standards, the above listed influences are set to zero in the following simulations. This is done, because the influence of the calibration standards is at the core of the investigations in this work. For the error network of the VNA in the simulation, typical values for source match, directivity, and tracking within the used frequency range up to <inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:mn mathvariant="normal">33</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/></mml:mrow></mml:math></inline-formula>GHz are assumed.</p>
      <p id="d1e354">In all simulations the used one-port standards are Open, Short, and Match (OSM). For simplification, the measurement uncertainties are assumed to be identical for those three standards and are plotted in Fig. <xref ref-type="fig" rid="Ch1.F4"/> for two different scenarios.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F4"><?xmltex \currentcnt{4}?><?xmltex \def\figurename{Figure}?><label>Figure 4</label><caption><p id="d1e362">Standard uncertainty of the coaxial calibration standards.</p></caption>
        <?xmltex \igopts{width=236.157874pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f04.png"/>

      </fig>

      <p id="d1e371">For the first scenario the uncertainties are identical for both adapter interfaces (A), here the coaxial connectors <inline-formula><mml:math id="M10" display="inline"><mml:mn mathvariant="normal">3.5</mml:mn></mml:math></inline-formula> and <inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.4</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/></mml:mrow></mml:math></inline-formula>mm. For the second scenario the MUs are higher for the <inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:mn mathvariant="normal">2.4</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/></mml:mrow></mml:math></inline-formula>mm interface (B).</p>
      <p id="d1e399">In the simulation the adapter could in theory consist of any reciprocal two-port data. Here, to have a reasonably good representation of a real adapter, it is modeled from two cascaded sections of beadless air-dielectric lines using the algorithm of <xref ref-type="bibr" rid="bib1.bibx1" id="text.11"/> and the parameter given in Table <xref ref-type="table" rid="Ch1.T1"/>.</p>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T1"><?xmltex \currentcnt{1}?><label>Table 1</label><caption><p id="d1e410">Parameter for modeling the coaxial adapter.</p></caption><oasis:table frame="topbot"><?xmltex \begin{scaleboxenv}{.98}[.98]?><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">3.5 mm section</oasis:entry>
         <oasis:entry colname="col3">2.4 mm section</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Outer conductor diameter</oasis:entry>
         <oasis:entry colname="col2">3.50 mm</oasis:entry>
         <oasis:entry colname="col3">2.40 mm</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Inner conductor diameter</oasis:entry>
         <oasis:entry colname="col2">1.55 mm</oasis:entry>
         <oasis:entry colname="col3">1.00 mm</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Conductivity</oasis:entry>
         <oasis:entry colname="col2">20 MS m<inline-formula><mml:math id="M13" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">20 MS m<inline-formula><mml:math id="M14" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Length</oasis:entry>
         <oasis:entry colname="col2">20 mm</oasis:entry>
         <oasis:entry colname="col3">17 mm</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup><?xmltex \end{scaleboxenv}?></oasis:table></table-wrap>

      <p id="d1e511">To create some significant reflection in a system with a reference impedance of <inline-formula><mml:math id="M15" display="inline"><mml:mrow><mml:mn mathvariant="normal">50</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula>, the impedances of both sections slightly deviate from <inline-formula><mml:math id="M16" display="inline"><mml:mrow><mml:mn mathvariant="normal">50</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="normal">Ω</mml:mi></mml:mrow></mml:math></inline-formula>. The <inline-formula><mml:math id="M17" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters of the adapter are given in Figs. <xref ref-type="fig" rid="Ch1.F5"/> and <xref ref-type="fig" rid="Ch1.F6"/>.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F5"><?xmltex \currentcnt{5}?><?xmltex \def\figurename{Figure}?><label>Figure 5</label><caption><p id="d1e550"><inline-formula><mml:math id="M18" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters (magnitude) of the simulated adapter.</p></caption>
        <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f05.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F6"><?xmltex \currentcnt{6}?><?xmltex \def\figurename{Figure}?><label>Figure 6</label><caption><p id="d1e567"><inline-formula><mml:math id="M19" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters (phase) of the simulated adapter.</p></caption>
        <?xmltex \igopts{width=241.848425pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f06.png"/>

      </fig>

      <p id="d1e582">The nominal results for both VNA calibrations (OSM and UOSM), namely the <inline-formula><mml:math id="M20" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters of the coaxial adapter, agree perfectly (<inline-formula><mml:math id="M21" display="inline"><mml:mrow><mml:mo>∼</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">16</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, numerical limit for double precision variables) with the data fed into the simulation. As the one-port method was started both at VNA port 1 and VNA port 2, six calibrations overall are investigated. The obtained MUs (<inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:mn mathvariant="normal">95</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> confidence interval) are plotted in Figs. <xref ref-type="fig" rid="Ch1.F7"/> and <xref ref-type="fig" rid="Ch1.F8"/>.</p>

      <?xmltex \floatpos{t}?><?pagebreak page4?><fig id="Ch1.F7" specific-use="star"><?xmltex \currentcnt{7}?><?xmltex \def\figurename{Figure}?><label>Figure 7</label><caption><p id="d1e625">MU of the obtained <inline-formula><mml:math id="M23" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters magnitude of the simulated adapter.</p></caption>
        <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f07.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F8" specific-use="star"><?xmltex \currentcnt{8}?><?xmltex \def\figurename{Figure}?><label>Figure 8</label><caption><p id="d1e644">MU of the obtained <inline-formula><mml:math id="M24" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters phase of the simulated adapter.</p></caption>
        <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f08.png"/>

      </fig>

      <p id="d1e660">As can be seen, the MU for the transmission parameters (<inline-formula><mml:math id="M25" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">21</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">12</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) are identical within in numerical precision for both magnitude and phase for the applied calibrations for both scenarios (equal and unequal MU for the OSM standards), respectively. Significant differences occur for the reflection parameters (<inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">22</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>). Here, the following observations are pointed out:
<list list-type="bullet"><list-item>
      <p id="d1e709">The phase MU is highest for smallest nominal values (here reflection coefficients).</p></list-item><list-item>
      <p id="d1e713">The OSM method achieves the smallest MU.</p></list-item><list-item>
      <p id="d1e717">Larger MU at one VNA port (here Port 2) also increases the MU at the other VNA port (here Port 1).</p></list-item><list-item>
      <p id="d1e721">Starting the OSM method at VNA Port 1 or 2 yields different MU.</p></list-item></list>
The third point was kind of unexpected, and the last point depends on the DUT as well as the VNA raw performance. For a perfectly symmetrical adapter and identical error parameter for each VNA port, the MU should be identical for both reflection parameters. Both was not the case in this simulation to bring some attention to this effect.</p>
      <p id="d1e725">To better understand the source of the MU, the MU budgets are calculated and plotted in the Figs. <xref ref-type="fig" rid="Ch1.F9"/> to <xref ref-type="fig" rid="Ch1.F12"/> for the OSM method starting at VNA Port 1. The MU budgets for the other calibration methods (OSM starting with the other port and UOSM) are similar. The adapter itself serves as a reciprocal calibration standard for the unknown thru measurement, and it would not contribute to the MU.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F9" specific-use="star"><?xmltex \currentcnt{9}?><?xmltex \def\figurename{Figure}?><label>Figure 9</label><caption><p id="d1e734">Uncertainty budget (<inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:mn mathvariant="normal">95</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> confidence interval) for the adapter <inline-formula><mml:math id="M30" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters magnitude, while assuming equal uncertainties for both calibration standard types.</p></caption>
        <?xmltex \igopts{width=398.338583pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f09.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F10" specific-use="star"><?xmltex \currentcnt{10}?><?xmltex \def\figurename{Figure}?><label>Figure 10</label><caption><p id="d1e763">Uncertainty budget (<inline-formula><mml:math id="M31" display="inline"><mml:mrow><mml:mn mathvariant="normal">95</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> confidence interval) for the adapter <inline-formula><mml:math id="M32" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters phase, while assuming equal uncertainties for both calibration standard types.</p></caption>
        <?xmltex \igopts{width=398.338583pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f10.png"/>

      </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T2"><?xmltex \currentcnt{2}?><label>Table 2</label><caption><p id="d1e794">Uncertainty budget of <inline-formula><mml:math id="M33" display="inline"><mml:mrow><mml:mo>|</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub><mml:mo>|</mml:mo></mml:mrow></mml:math></inline-formula> for both calibration methods at <inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:mn mathvariant="normal">15</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/></mml:mrow></mml:math></inline-formula>GHz.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Uncertainty</oasis:entry>
         <oasis:entry colname="col3">Uncertainty</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">components</oasis:entry>
         <oasis:entry colname="col3">components</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">of the OSM</oasis:entry>
         <oasis:entry colname="col3">of the UOSM</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">method in %</oasis:entry>
         <oasis:entry colname="col3">method in %</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Standards</oasis:entry>
         <oasis:entry colname="col2">77.364</oasis:entry>
         <oasis:entry colname="col3">83.482</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Connection</oasis:entry>
         <oasis:entry colname="col2">21.615</oasis:entry>
         <oasis:entry colname="col3">12.292</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">repeatability</oasis:entry>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">VNA Drift</oasis:entry>
         <oasis:entry colname="col2">0.765</oasis:entry>
         <oasis:entry colname="col3">0.392</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">VNA Linearity</oasis:entry>
         <oasis:entry colname="col2">0.245</oasis:entry>
         <oasis:entry colname="col3">3.703</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">VNA Noise</oasis:entry>
         <oasis:entry colname="col2">0.011</oasis:entry>
         <oasis:entry colname="col3">0.131</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e953">Noteworthy things to point out are:
<list list-type="bullet"><list-item>
      <p id="d1e958">The MU of the calibration standards used at one VNA port are also part of the MU budget at the other VNA port.</p></list-item><list-item>
      <p id="d1e962">The Match standards determine the MU of the well matched reflection coefficients.</p></list-item><list-item>
      <?pagebreak page5?><p id="d1e966">The high reflect standards (Open and Short) determine the MU of the transmission coefficients.</p></list-item></list></p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F11" specific-use="star"><?xmltex \currentcnt{11}?><?xmltex \def\figurename{Figure}?><label>Figure 11</label><caption><p id="d1e971">Uncertainty budget (<inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:mn mathvariant="normal">95</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> confidence interval) for the adapter <inline-formula><mml:math id="M36" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters magnitude, while assuming different uncertainties for both calibration standard types.</p></caption>
        <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f11.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F12" specific-use="star"><?xmltex \currentcnt{12}?><?xmltex \def\figurename{Figure}?><label>Figure 12</label><caption><p id="d1e1000">Uncertainty budget (<inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:mn mathvariant="normal">95</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> confidence interval) for the adapter <inline-formula><mml:math id="M38" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula>-parameters phase, while assuming different uncertainties for both calibration standard types.</p></caption>
        <?xmltex \igopts{width=369.885827pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f12.png"/>

      </fig>

      <?xmltex \floatpos{t}?><fig id="Ch1.F13"><?xmltex \currentcnt{13}?><?xmltex \def\figurename{Figure}?><label>Figure 13</label><caption><p id="d1e1030">Graphical representation of the complete measurement procedure. The colors blue and red indicate different interfaces and therefore different calibrations standards, each set mating with one side of the adapter to be characterized.</p></caption>
        <?xmltex \igopts{width=184.942913pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f13.png"/>

      </fig>

</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Measurements</title>
<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Procedure</title>
      <p id="d1e1054">To confirm the simulations results, measurements are carried out. Figure <xref ref-type="fig" rid="Ch1.F13"/> shows the measurement procedure for the comparison of both methods. The order of steps are chosen in a way to have few connections and measurements overall and to use as many results for both methods as possible. Each connection and measurement is usually performed three to four times in practice, to enable an evaluation of the connection repeatability.</p>

      <?xmltex \floatpos{t}?><fig id="Ch1.F14" specific-use="star"><?xmltex \currentcnt{14}?><?xmltex \def\figurename{Figure}?><label>Figure 14</label><caption><p id="d1e1061">Measurement results including MU for PC2.4 to PC3.5<inline-formula><mml:math id="M39" display="inline"><mml:mspace width="0.125em" linebreak="nobreak"/></mml:math></inline-formula>mm (black-dashed OSM and red-solid UOSM).</p></caption>
          <?xmltex \igopts{width=341.433071pt}?><graphic xlink:href="https://ars.copernicus.org/articles/20/1/2023/ars-20-1-2023-f14.png"/>

        </fig>

<?xmltex \floatpos{t}?><table-wrap id="Ch1.T3" specific-use="star"><?xmltex \currentcnt{3}?><label>Table 3</label><caption><p id="d1e1079">Necessary steps and connections for both calibration methods, when measuring multiple DUTs.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1">Number</oasis:entry>
         <oasis:entry colname="col2">Steps</oasis:entry>
         <oasis:entry colname="col3">Steps</oasis:entry>
         <oasis:entry colname="col4">UOSM without</oasis:entry>
         <oasis:entry colname="col5">Connections</oasis:entry>
         <oasis:entry colname="col6">Connections</oasis:entry>
         <oasis:entry colname="col7">UOSM without</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">of DUTs</oasis:entry>
         <oasis:entry colname="col2">for OSM</oasis:entry>
         <oasis:entry colname="col3">for UOSM</oasis:entry>
         <oasis:entry colname="col4">cable movement</oasis:entry>
         <oasis:entry colname="col5">for OSM</oasis:entry>
         <oasis:entry colname="col6">for UOSM</oasis:entry>
         <oasis:entry colname="col7">cable movement</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">1</oasis:entry>
         <oasis:entry colname="col2">7</oasis:entry>
         <oasis:entry colname="col3">7</oasis:entry>
         <oasis:entry colname="col4">7</oasis:entry>
         <oasis:entry colname="col5">7</oasis:entry>
         <oasis:entry colname="col6">8</oasis:entry>
         <oasis:entry colname="col7">8</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2</oasis:entry>
         <oasis:entry colname="col2">11</oasis:entry>
         <oasis:entry colname="col3">8</oasis:entry>
         <oasis:entry colname="col4">11</oasis:entry>
         <oasis:entry colname="col5">11</oasis:entry>
         <oasis:entry colname="col6">10</oasis:entry>
         <oasis:entry colname="col7">13</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">3</oasis:entry>
         <oasis:entry colname="col2">15</oasis:entry>
         <oasis:entry colname="col3">9</oasis:entry>
         <oasis:entry colname="col4">15</oasis:entry>
         <oasis:entry colname="col5">15</oasis:entry>
         <oasis:entry colname="col6">12</oasis:entry>
         <oasis:entry colname="col7">18</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">4</oasis:entry>
         <oasis:entry colname="col2">19</oasis:entry>
         <oasis:entry colname="col3">10</oasis:entry>
         <oasis:entry colname="col4">19</oasis:entry>
         <oasis:entry colname="col5">19</oasis:entry>
         <oasis:entry colname="col6">14</oasis:entry>
         <oasis:entry colname="col7">22</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d1e1259">In the first step the OSM standards are measured at VNA Port 1. The results are used for the calibration in both methods. Afterwards the DUT is attached to the fist port and the second set of OSM standards are measured. These results are only used for the one-port method. For the UOSM method the DUT (adapter) is inserted, while only moving the cable at the second port. When disconnecting after this<?pagebreak page6?> measurement, only the cable at Port 1 is moved and the measurements of the OSM calibration standards are repeated for the second port. This procedure avoids cable movements completely, to provide fair comparison conditions for both methods.</p>
      <p id="d1e1262">From this procedure, it can be clearly seen that is it not possible to measure more than one thru or two-port DUT consecutively, while still avoiding cable movements. If more than one two-port DUT needs to be measured, one set of one-port standards needs to be measured again at the VNA port, at which the cable was moved since the last measurement of the one-port standards. Otherwise, the MU due to cable movements are to be included.</p>
</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Results</title>
      <p id="d1e1273">The measurements and evaluation for both the one-port and two-port calibration method are performed using <xref ref-type="bibr" rid="bib1.bibx9" id="text.12"/>; <xref ref-type="bibr" rid="bib1.bibx12" id="text.13"/>. Including cable movements would cause only a minor change in the MU of the reflections parameters. But even with high quality cables (<xref ref-type="bibr" rid="bib1.bibx6" id="altparen.14"/>), the MU of the transmission parameters would generally increase by 0.001 or more<?pagebreak page7?> in magnitude and several degrees in phase. Both magnitude and phase MU are a function of frequency, but the cable contribution would dominate over the complete frequency range.</p>
      <p id="d1e1285">The obtained measurement results for both methods are shown in Fig. <xref ref-type="fig" rid="Ch1.F14"/>. The MU (<inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:mn mathvariant="normal">95</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> confidence interval) indicated by the transparent area in the plot also includes VNA drift, VNA noise, VNA linearity and connection repeatability in addition to the MU of the calibration standards analyzed in the simulation in Sect. <xref ref-type="sec" rid="Ch1.S3"/>. During the measurement the one-port calibration method was started at Port 1 and the MU obtained in the measurement confirms the simulation results shown in Fig. <xref ref-type="fig" rid="Ch1.F7"/> with a lower uncertainty for the OSM method at Port 1 and a higher one, when compared to the UOSM method at Port 2.</p>
      <p id="d1e1305">Table <xref ref-type="table" rid="Ch1.T2"/> shows the detailed MU budget of <inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:mo>|</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub><mml:mo>|</mml:mo></mml:mrow></mml:math></inline-formula> at <inline-formula><mml:math id="M42" display="inline"><mml:mrow><mml:mn mathvariant="normal">15</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/></mml:mrow></mml:math></inline-formula>GHz for both calibration methods. Even with precise calibration standards used here, their contribution dominates the MU. Second largest influence is the connection repeatability, and the VNA itself plays a very minor MU role. The last point is due to the VNA beeing a high quality metrology grade device and beeing operated in a laboratory with excellent environmental control (temperature and humidity).</p>
</sec>
</sec>
<sec id="Ch1.S5">
  <label>5</label><title>Comparison of Both Methods</title>
      <p id="d1e1343">It can be concluded that the overall MU for both calibration methods is of comparable magnitude and that the uncertainties of the calibration standards are the main contributor, if cable movement is avoided. However, the number of required connections is not the same for both methods.</p>
      <p id="d1e1346">The number of required steps and connections for measuring up to four DUTs are summarized in Table <xref ref-type="table" rid="Ch1.T3"/>. Here, one step is one measurement to be recorded and one connection is one physical connection to be made, resulting in two connections for a two-port DUT. As mentioned above, each of these connections is usually made three to four times to evaluate the repeatability (not shown in the table). For both methods the number of necessary connections rises quickly with the number of DUTs to be measured, if cable movements are avoided, to obtain a low MU. However, including cable movements the UOSM method becomes more efficient, when several DUTs are to be measured.</p>
      <p id="d1e1351">In addition to the time needed to perform a large number of connections also the wear on the used measurement adapter and the calibration standards should be considered. While several thousand connections are often possible with coaxial interfaces, the quality (repeatability) might start to degrade after a couple of hundred connections.</p>
      <?pagebreak page8?><p id="d1e1354"><?xmltex \hack{\newpage}?>When measuring multiple DUTs while avoiding cable movements, new error networks must be derived and applied for each DUT. This is additional effort in evaluating the measurement and it is also somewhat error prone. For a large number of DUTs the UOSM method with cable movements is time efficient, results in less wear on the equipment and, as only one set of error networks is needed, the error correction is simpler. The MU however is increased due to the cable movements.</p>
</sec>
<sec id="Ch1.S6" sec-type="conclusions">
  <label>6</label><title>Conclusions</title>
      <p id="d1e1366">Both calibration methods compared in this paper are suitable to measure adapters and yield low MU. Depending on the required precision and e.g. allowing for cable movements, the UOSM method requires fewer connections and is therefore faster. Even with state of the art measurement cables, cable movements might increase the MU significantly and should be avoided or minimized.</p>
      <p id="d1e1369">Ultimately, the decision which method should be applied for adapter measurements is always a trade-off and depends on the desired MU, the expenditure of time and the wear on the laboratory equipment.</p>
</sec>

      
      </body>
    <back><notes notes-type="codedataavailability"><title>Code and data availability</title>

      <p id="d1e1376">No software code or research data is available for the presented work, but all results can be reproduced with the
equations and parameters given here.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e1383">KK had the idea, did the simulations, and wrote most of the manuscript. FG supported the evaluation of the measurement data and wrote parts of the manuscript. MT designed the experiment, carried it out, and prepared the results.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e1389">The contact author has declared that none of the authors has any competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d1e1395">Publisher’s note: Copernicus Publications remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.</p>
  </notes><notes notes-type="sistatement"><title>Special issue statement</title>

      <p id="d1e1401">This article is part of the special issue “Kleinheubacher Berichte 2021”.</p>
  </notes><ack><title>Acknowledgements</title><p id="d1e1407">The authors would like to thank Florian Rausche for his support end expertise during the measurements and evaluation of the obtained data.</p></ack><?xmltex \hack{\newpage}?><?xmltex \hack{\newpage}?><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e1413">This open-access publication was funded <?xmltex \notforhtml{\newline}?> by the Physikalisch-Technische Bundesanstalt.</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e1421">This paper was edited by Madhu Chandra and reviewed by Madhu Chandra and one anonymous referee.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><?xmltex \def\ref@label{{Daywitt(1990)}}?><label>Daywitt(1990)</label><?label Daywitt1990?><mixed-citation>Daywitt, W. C.: First-Order Symmetric Modes for a Slightly Lossy Coaxial
Transmission Line, IEEE T. Microw. Theory, 38, 1644–1650, <ext-link xlink:href="https://doi.org/10.1109/22.60011" ext-link-type="DOI">10.1109/22.60011</ext-link>,
1990.</mixed-citation></ref>
      <ref id="bib1.bibx2"><?xmltex \def\ref@label{{Ferrero and Pisani(1992)}}?><label>Ferrero and Pisani(1992)</label><?label ferrero1992?><mixed-citation>Ferrero, A. and Pisani, U.: Two-port network analyzer calibration using an
unknown “thru”, IEEE Microw. Guided W., 2, 505–507,
<ext-link xlink:href="https://doi.org/10.1109/75.173410" ext-link-type="DOI">10.1109/75.173410</ext-link>, 1992.</mixed-citation></ref>
      <ref id="bib1.bibx3"><?xmltex \def\ref@label{{Hiebel(2007)}}?><label>Hiebel(2007)</label><?label Hiebel2007?><mixed-citation>
Hiebel, M.: Grundlagen der vektoriellen Netzwerkanalyse, Rohde und Schwarz
GmbH, 2nd edn., ISBN 978-3-939837-05-3, 2007.</mixed-citation></ref>
      <ref id="bib1.bibx4"><?xmltex \def\ref@label{{Marks(1997)}}?><label>Marks(1997)</label><?label marks1997?><mixed-citation>Marks, R. B.: Formulations of the Basic Vector Network Analyzer Error Model
including Switch-Terms, in: 50th ARFTG Conference Digest, Portland, OR, USA,  4–5 December 1997, 32,
115–126, <ext-link xlink:href="https://doi.org/10.1109/ARFTG.1997.327265" ext-link-type="DOI">10.1109/ARFTG.1997.327265</ext-link>, 1997.</mixed-citation></ref>
      <ref id="bib1.bibx5"><?xmltex \def\ref@label{{Mathworks(2021)}}?><label>Mathworks(2021)</label><?label Matlab?><mixed-citation>Mathworks: MATLAB 2019a, <uri>https://de.mathworks.com/</uri> (last access: 17 February 2023), 2021.</mixed-citation></ref>
      <ref id="bib1.bibx6"><?xmltex \def\ref@label{{Moder and Schubert(2022)}}?><label>Moder and Schubert(2022)</label><?label moder2022?><mixed-citation>Moder, M. and Schubert, J.: Charaterization of RF and Microwave Measurement
Cables Used with Vector Network Analyzers, Tech. Rep. 2, Microwave Journal,
<ext-link xlink:href="https://www.microwavejournal.com/articles/37588-characterization-of-rf-and-microwave-measurement-cables-used-with-vector-network-analyzers?page=1">https://www.microwavejournal.com/articles/37588-characterization-of-rf-and-microwave-measurement-cables-used-with-vector-network-analyzers?page=1</ext-link>  (last access: 17 February 2023),  2022.</mixed-citation></ref>
      <ref id="bib1.bibx7"><?xmltex \def\ref@label{{Ruefenacht and the METAS VNA~gang(2016)}}?><label>Ruefenacht and the METAS VNA gang(2016)</label><?label Ruefenacht2016a?><mixed-citation>Ruefenacht, J. and the METAS VNA gang: Adapter characterization up to 110 GHz,
EMRP HF Circuits project: 6th European ANAMET meeting, slides, Teddington, UK,  June 2016, <ext-link xlink:href="https://doi.org/10.13140/RG.2.1.4947" ext-link-type="DOI">10.13140/RG.2.1.4947</ext-link>, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx8"><?xmltex \def\ref@label{{Stumper(2008)}}?><label>Stumper(2008)</label><?label Stumper2008?><mixed-citation>Stumper, U.: Uncertainties of VNA S-parameter measurements applying the
Short-Open-Load-reciprocal (SOLR) calibration method, in: 2008 Conference on
Precision Electromagnetic Measurements Digest,  Broomfield, CO, USA,  8–13 June 2008, 438–439,
<ext-link xlink:href="https://doi.org/10.1109/CPEM.2008.4574841" ext-link-type="DOI">10.1109/CPEM.2008.4574841</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx9"><?xmltex \def\ref@label{{Wollensack and Hoffmann(2019)}}?><label>Wollensack and Hoffmann(2019)</label><?label Wollensack2019?><mixed-citation>Wollensack, M. and Hoffmann, J.: METAS VNA Tools II – Math Reference V2.2.6,
Tech. Rep. 2.2.6, METAS, Bern, Switzerland, <uri>https://www.metas.ch/dam/metas/en/data/Fachbereiche/Hochfrequenz/vna-tools/version262/VnaToolsMath V2.6.2.pdf.download.pdf/VnaToolsMath V2.6.2.pdf</uri>  (last access: 17 February 2023), 2019.</mixed-citation></ref>
      <ref id="bib1.bibx10"><?xmltex \def\ref@label{{{Working Group 1 of the Joint Committee for Guides in
Metrology}(2008)}}?><label>Working Group 1 of the Joint Committee for Guides in
Metrology(2008)</label><?label WGJCGM2008?><mixed-citation>Working Group 1 of the Joint Committee for Guides in Metrology: Evaluation
of measurement data – Guide to the expression of uncertainty in
measurement, JCGM,  <uri>https://www.bipm.org/documents/20126/2071204/JCGM_100_2008_E.pdf/cb0ef43f-baa5-11cf-3f85-4dcd86f77bd6</uri> (last access: 17 February 2023), 2008.</mixed-citation></ref>
      <ref id="bib1.bibx11"><?xmltex \def\ref@label{{{Zeier} et~al.(2012){Zeier}, {Hoffmann}, and
{Wollensack}}}?><label>Zeier et al.(2012)Zeier, Hoffmann, and
Wollensack</label><?label Zeier2012?><mixed-citation>Zeier, M., Hoffmann, J., and Wollensack, M.: Metas.UncLib-a
measurement uncertainty calculator for advanced problems, Metrologia, 49,
809–815, <ext-link xlink:href="https://doi.org/10.1088/0026-1394/49/6/809" ext-link-type="DOI">10.1088/0026-1394/49/6/809</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx12"><?xmltex \def\ref@label{{Zeier et~al.(2018)Zeier, Allal, and Judaschke}}?><label>Zeier et al.(2018)Zeier, Allal, and Judaschke</label><?label Zeier2018c?><mixed-citation>
Zeier, M., Allal, D., and Judaschke, R.: Guidelines on the Evaluation of
Vector Network Analysers (VNA), ISBN: 978-3-942992-51-0, 2018.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Comparison of <i>S</i>-Parameter Measurement Methods for Adapters</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>Daywitt(1990)</label><mixed-citation>
      
Daywitt, W. C.: First-Order Symmetric Modes for a Slightly Lossy Coaxial
Transmission Line, IEEE T. Microw. Theory, 38, 1644–1650, <a href="https://doi.org/10.1109/22.60011" target="_blank">https://doi.org/10.1109/22.60011</a>,
1990.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Ferrero and Pisani(1992)</label><mixed-citation>
      
Ferrero, A. and Pisani, U.: Two-port network analyzer calibration using an
unknown “thru”, IEEE Microw. Guided W., 2, 505–507,
<a href="https://doi.org/10.1109/75.173410" target="_blank">https://doi.org/10.1109/75.173410</a>, 1992.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Hiebel(2007)</label><mixed-citation>
      
Hiebel, M.: Grundlagen der vektoriellen Netzwerkanalyse, Rohde und Schwarz
GmbH, 2nd edn., ISBN 978-3-939837-05-3, 2007.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Marks(1997)</label><mixed-citation>
      
Marks, R. B.: Formulations of the Basic Vector Network Analyzer Error Model
including Switch-Terms, in: 50th ARFTG Conference Digest, Portland, OR, USA,  4–5 December 1997, 32,
115–126, <a href="https://doi.org/10.1109/ARFTG.1997.327265" target="_blank">https://doi.org/10.1109/ARFTG.1997.327265</a>, 1997.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Mathworks(2021)</label><mixed-citation>
      
Mathworks: MATLAB 2019a, <a href="https://de.mathworks.com/" target="_blank"/> (last access: 17 February 2023), 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Moder and Schubert(2022)</label><mixed-citation>
      
Moder, M. and Schubert, J.: Charaterization of RF and Microwave Measurement
Cables Used with Vector Network Analyzers, Tech. Rep. 2, Microwave Journal,
<a href="https://www.microwavejournal.com/articles/37588-characterization-of-rf-and-microwave-measurement-cables-used-with-vector-network-analyzers?page=1" target="_blank">https://www.microwavejournal.com/articles/37588-characterization-of-rf-and-microwave-measurement-cables-used-with-vector-network-analyzers?page=1</a>  (last access: 17 February 2023),  2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Ruefenacht and the METAS VNA gang(2016)</label><mixed-citation>
      
Ruefenacht, J. and the METAS VNA gang: Adapter characterization up to 110 GHz,
EMRP HF Circuits project: 6th European ANAMET meeting, slides, Teddington, UK,  June 2016, <a href="https://doi.org/10.13140/RG.2.1.4947" target="_blank">https://doi.org/10.13140/RG.2.1.4947</a>, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Stumper(2008)</label><mixed-citation>
      
Stumper, U.: Uncertainties of VNA S-parameter measurements applying the
Short-Open-Load-reciprocal (SOLR) calibration method, in: 2008 Conference on
Precision Electromagnetic Measurements Digest,  Broomfield, CO, USA,  8–13 June 2008, 438–439,
<a href="https://doi.org/10.1109/CPEM.2008.4574841" target="_blank">https://doi.org/10.1109/CPEM.2008.4574841</a>, 2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Wollensack and Hoffmann(2019)</label><mixed-citation>
      
Wollensack, M. and Hoffmann, J.: METAS VNA Tools II – Math Reference V2.2.6,
Tech. Rep. 2.2.6, METAS, Bern, Switzerland, <a href="https://www.metas.ch/dam/metas/en/data/Fachbereiche/Hochfrequenz/vna-tools/version262/VnaToolsMath V2.6.2.pdf.download.pdf/VnaToolsMath V2.6.2.pdf" target="_blank"/>  (last access: 17 February 2023), 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Working Group 1 of the Joint Committee for Guides in
Metrology(2008)</label><mixed-citation>
      
Working Group 1 of the Joint Committee for Guides in Metrology: Evaluation
of measurement data – Guide to the expression of uncertainty in
measurement, JCGM,  <a href="https://www.bipm.org/documents/20126/2071204/JCGM_100_2008_E.pdf/cb0ef43f-baa5-11cf-3f85-4dcd86f77bd6" target="_blank"/> (last access: 17 February 2023), 2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Zeier et al.(2012)Zeier, Hoffmann, and
Wollensack</label><mixed-citation>
      
Zeier, M., Hoffmann, J., and Wollensack, M.: Metas.UncLib-a
measurement uncertainty calculator for advanced problems, Metrologia, 49,
809–815, <a href="https://doi.org/10.1088/0026-1394/49/6/809" target="_blank">https://doi.org/10.1088/0026-1394/49/6/809</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Zeier et al.(2018)Zeier, Allal, and Judaschke</label><mixed-citation>
      
Zeier, M., Allal, D., and Judaschke, R.: Guidelines on the Evaluation of
Vector Network Analysers (VNA), ISBN: 978-3-942992-51-0, 2018.

    </mixed-citation></ref-html>--></article>